DUCTED SYSTEMS HEATING AND COOLING SOLUTIONS - Mitsubishi Heavy Industries
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
IED CUS TISF TO SA ST M 2019 ER MO S IR ER S A CO NDITION HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS
IED CUS TISF TO SA ST M 2019 ER MO S IR ER S A CO NDITION AUSTRALIA'S BEST AIR CONDITIONER BRAND We’re proud to have been named by CHOICE® as Australia’s best brand of air conditioner for the second year in a row whilst also being named by Canstar Blue as having the most satisfied customers of any air conditioner brand in Australia. If you’re considering replacing or upgrading your air conditioner, why not choose the best? MITSUBISHI HEAVY INDUSTRIES COMMITTED TO QUALITY AIR CONDITIONERS AUSTRALIA Standing behind the quality of our products, is our commitment to our customers and our after sales service guarantees. Along with the rigorous quality assurance testing carried out on all Mitsubishi Heavy Industries Mitsubishi Heavy Industries Air-Conditioners Australia (MHIAA) is one of Australia’s products, comprehensive warranties provide you with peace of mind and carry our commitment to quality. leading suppliers of premium residential and commercial air conditioning systems. Delivering engineering excellence for over 130 years, the Mitsubishi Heavy Industries brand is instantly recognisable for quality and technological advancement. With innovation central to both the organisation and the development of air conditioning systems, Mitsubishi Heavy Industries carries a strong philosophy of engineering products that are designed to improve the lives 5 YEARS PARTS AND LABOUR WARRANTY of those who use them and, at the same time, create a sustainable future for our company and the world we live in. Mitsubishi Heavy Industries Air conditioners Australia focuses solely on manufacturing high performance air conditioners for the Australian market. All our systems are of the highest quality and are backed by a full 5 year parts and labour warranty. BRAND AMBASSADOR TARA DENNIS Interior designer and Television presenter Tara Dennis joins Mitsubishi Heavy Industries Air-Conditioners Australia as the brand’s first ambassador to Australia EXCEEDING ENERGY and New Zealand. With extensive experience in home decoration and design, Tara represents the home renovator looking to improve the design of their homes. PERFORMANCE STANDARDS “As someone who has a passion for styling and renovating you want to push To comply with Australian standards and deliver the most efficient solutions possible to MEPS the boundaries and create a space that people love being in. Mitsubishi Heavy our customers, all Mitsubishi Heavy Industries Air conditioners Australia systems meet and COMPLIANT Industries Air conditioners Australia is the perfect extension of this and a brand that exceed the Minimum Energy Performance Standards (MEPS). I am proud to be supporting” 2 3
MHIAA Ducted Systems Our Technology Our powerful yet quiet reverse cycle ducted systems let you enjoy the comfort of air conditioning in every part of your home or office with one packaged solution. With a discreet, low profile design that can be completely IMPROVED HEAT COATED PCB BLUE FIN concealed in your ceiling and a variety of capacities and control options available, our ducted systems offer a EXCHANGER To protect against humid TECHNOLOGY flexible solution for any new or existing home. weather a protective coating Our new and improved heat Mitsubishi Heavy Industries is applied to the circuit board Mitsubishi Heavy Industries ducted systems include an indoor unit (fan coil), outdoor unit (condenser) and exchanger has been developed outdoor units are coated with in the outdoor unit, allowing controller while an installer will also incorporate insulated ducting, air outlets and a return air inlet with a filter. to improve refrigerant distribution specially formulated layers it to withstand Australia’s These components work in unison to offer a complete heating and cooling solution and ensure your comfort all and increase the systems that assist in preventing the varying weather conditions year round. effectiveness. The new design hydrophilicity effect and assists and ensure the longevity of features a larger heat exchange in reducing the corrosion your system. All Mitsubishi Heavy Industries ducted systems are reverse cycle and have undergone strict and rigorous testing area, boosting the unit’s overall rate of the aluminium section and quality control measures to ensure they are of the highest standards and will withstand the tough Australian efficiency. from harsh Australian weather climate. conditions. BLUE FIN COATED TECHNOLOGY PCB DUCTING TO DISTRIBUTE AIR THROUGHOUT YOUR HOME IMPROVED HEAT EXCHANGER OUTLETS HIGH EFFICIENCY SMALL COMPRESSOR REFRIGERANT PIPING RETURN AIR INLET WITH FILTER HIGH EFFICIENCY DC PAM WIDE OPERATION COMPRESSOR INVERTER RANGE INDOOR One of the key features that The PAM control used in With our advanced technology provides Mitsubishi Heavy Mitsubishi Heavy Industries and high quality components, UNIT Industries air conditioners with air conditioners helps Mitsubishi Heavy Industries air their powerful performance is minimise the loss of electricity conditioners can operate in our highly efficient compressor. and boost the efficiency by ambient outdoor temperatures OUTDOOR Combined with a Neodymium allowing the unit to reach as low as -20˚C in heating mode UNIT motor that uses powerful, rare the temperature quickly and as high as +46˚C in cooling earth magnets, Mitsubishi Heavy before slowing down the mode. Industries air conditioners can compressor. This allows the This permits the installation in deliver a higher motor efficiency unit to save energy while areas where the temperature while producing much less maintaining a comfortable conditions can be considered operational noise. temperature in the room. extreme. 4 5
FDUM Series FDU Series REVERSE REVERSE CYCLE CYCLE NEW *See pg. 12 for full list of features and functions *See pg. 12 for full list of features and functions MEDIUM STATIC PRESSURE MED/HIGH STATIC PRESSURE SINGLE PHASE MODELS (5.0KW - 5.6KW) SINGLE PHASE MODELS (7.1 KW - 14.0KW) Energy Saving Hi Power Silent Operation Automatic Weekly/Sleep/ Self-Diagnostics THREE PHASE MODELS (12.5KW - 14.0KW) Energy Saving Hi Power Silent Operation Automatic Weekly/Sleep/ Self-Diagnostics Operation Peak-Cut Timer Operation Peak-Cut Timer 5.0kW | 5.6kW 7.1kW | 10.0kW | 12.5kW | 14.0kW Our FDUM series of medium static ducted systems are quiet, compact and come in both 5.0kW and 5.6kW ca- Our NEW FDU series of slimline ducted systems are a quiet and discreet solution for multiple rooms. Coming pacities. Incorporating a range of convenient and energy saving features and functions, the FDUM series is the in a range of capacities ranging from 7.1kW up to 14kW and incorporating a range of convenient features and perfect multi-room heating and cooling solution for smaller Aussie homes. functions, the FDU series is the perfect heating and cooling solution for any sized Aussie home. HYPER-INVERTER TECHNOLOGY IMPROVED SERVICEABILITY INCREASED ENERGY EFFICIENCY SLIM LOW PROFILE DESIGN Our advanced hyper-inverter technology allows Designed to improve serviceability the fan unit With an improved heat exchanger in the outdoor With a slim, low-profile design measuring only our ducted systems to reach the desired temper- (comprised of impeller and motor) in the FDUM unit, boosting refrigerant distribution throughout 280mm in height, the FDU series offers the perfect ature quicker than ever before. Once the system series can be easily accessed from either the side the system, coupled with our highly efficient DC solution for applications where ceiling space is has reached the set temperature it will ramp down or bottom of the unit and pulled out for trou- fan motor within the indoor unit, the FDU series limited. and maintain this closely, switching on only when ble-free maintenance. boasts industry leading energy efficiencies which required - ensuring your comfort all year round and means reduced running costs for your home. reducing energy consumption. QUIET OPERATION FLEXIBLE INSTALLATION QUIET OPERATION BALANCED AIRFLOW The FDUM series boasts a super quite operation With a built-in drain pump, which includes a lift of Thanks to our highly efficient DC fan motor, the FDU Given every home is different, the FDU range al- level of 25 dB (A) on low fan speed. Combined 600mm, the FDUM allows greater flexibility during series boasts some of the quietest operation levels lows the system’s static pressure to be set man- with the unit’s Silent Mode, the FDUM is perfect for installation, making it the perfect solution for on the market - with our 7.1kW unit achieving a ually during installation. This ensures the system bedrooms and ensures a good night’s sleep for you applications with limited ceiling space. market leading low of 25 dB (A) on low fan speed. delivers the perfect amount of airflow to each room and your family. Combined with the unit’s Silent Mode, the FDU - no matter what the setup, ensuring year round series ensures no interruptions to room acoustics comfort for everyone in your home. and a good night’s sleep for you and your family. OTHER CONTROL OPTIONS OTHER CONTROL OPTIONS (SOLD SEPARATELY) (SOLD SEPARATELY) Wi-Fi WIRELESS Wi-Fi WIRELESS 6 7
FDUA Series SRR Series REVERSE REVERSE CYCLE CYCLE *See pg. 12 for full list of features and functions *See pg. 12 for full list of features and functions HIGH STATIC PRESSURE BULKHEAD SYSTEM SINGLE PHASE MODELS (7.1 KW - 14.0KW) SINGLE PHASE MODELS (2.5KW - 3.5KW) THREE PHASE MODELS (12.5KW - 20.0KW) Energy Saving Hi Power Silent Operation Automatic Weekly/Sleep/ Self-Diagnostics Energy Saving Hi Power Silent Operation Automatic Weekly/Sleep/ Self-Diagnostics Operation Peak-Cut Timer Operation Peak-Cut Timer 7.1kW | 10.0kW | 12.5kW | 14.0kW |16.0kW | 20.0kW 2.5kW | 3.5 kW Our FDUA series of ducted systems are a quiet and discreet solution for multiple rooms. Coming in a range of Our low profile bulkhead systems are designed to sit within your ceiling space and distribute air via discreet capacities ranging from 7.1kW up to 20kW and incorporating a range of convenient features and functions, the grilles. These compact units require no ducting and are perfect for renovated spaces and applications such as FDUA is the perfect heating and cooling solution for any sized Aussie home. apartments where space is at a premium as they can be factored in to the finished design to provide a quiet, efficient and integrated heating and cooling solution. INCREASED ENERGY EFFICIENCY BALANCED AIRFLOW SUPER SLIM LOW PROFILE DESIGN SUPER QUIET OPERATION With an improved heat exchanger in the outdoor Given every home is different, the FDUA range With a super slim, low-profile design measuring The SRR series offers some of the quietest opera- unit, boosting refrigerant distribution throughout allows the system’s static pressure to be set man- only 200mm in height, the SRR series offers the tion levels on the market achieving 24 dB(A) on low the system, coupled with our highly efficient DC ually during installation. This ensures the system perfect solution for apartments or applications fan mode - perfect for bedrooms. fan motor within the indoor unit, the FDUA series delivers the perfect amount of airflow to each room where ceiling space is limited and the indoor unit boasts industry leading energy efficiencies which - no matter what the setup, ensuring year round needs to be fitted in a concealed area. means reduced running costs for your home. comfort for everyone in your home. QUIET OPERATION BUILT-IN DRAIN PUMP BUILT-IN DRAIN PUMP ECO MODE Thanks to our highly efficient DC fan motor, the Capitalising on Mitsubishi Heavy Industries ex- Capitalising on Mitsubishi Heavy Industries exten- Fuzzy logic algorithms allows the unit to accurately FDUA series boasts some of the quietest operation tensive experience in drain pump technology, the sive experience in drain pump technology, the SRR determine the most suitable operating mode, levels on the market - with our 7.1kW unit achieving FDUA series features a built-in condensation drain series features a built-in condensation drain pump temperature setting and automatically adjusts the a market leading low of 25 dB (A) on low fan speed. pump for easier installation. for easier installation. inverter frequency accordingly. Combined with the unit’s Silent Mode, the FDUA series ensures no interruptions to room acoustics and a good night’s sleep for you and your family. OTHER CONTROL OPTIONS OTHER CONTROL OPTIONS (SOLD SEPARATELY) (SOLD SEPARATELY) Wi-Fi WIRELESS Wi-Fi WIRED 8 9
Control Options FlexiZone Zoning Solution WIRED CONTROLLER WIRED ZONE CONTROLLER • Large, 3.8” backlit LCD touch screen with easy to navigate menu. • Individual on/off control of up to 4 zones when used in conjunction with • Control the set temperature, operation mode and fan speed. MHIAA’s zoning solution*. • Access timer and scheduling functions. • Large, 3.8” backlit LCD touch screen with easy to navigate menu. • Access additional features including Home Leave mode, Silent Mode, • Control the operation mode and set temperature of your system. High Power mode plus many more. • Access timer and scheduling functions. • Multi-language display (6 languages) • Access additional features including Home Leave mode, Silent Mode *RC-EXZ3A controller shown. and High Power mode. **Requires SC-BIKN2-E kit (sold separately) for use with bulkhead systems. ***Function limitations may apply. • Multi-language display (6 languages) FLEXIZONE ® *RC-EXZ3A controller shown. **MHIAA zoning solution includes relay board (MH-4ZRM). Transformer sold separately. OCCUPIED ZONE TURNED ON WIRELESS CONTROLLER • Easy to use wireless remote. • Large, LCD display. • Control the set temperature, operation mode and fan speed. OCCUPIED ZONE • Access timer and scheduling functions. TURNED ON *Wireless controller from RCN-KIT4-E2 shown. Standard with bulkhead systems. **Requires RCN-KIT4-E2 wireless kit (sold separately) for use with ducted systems. ***Function limitations may apply. UNOCCUPIED ZONE TURNED OFF Airzone Zoning Solution Easily integrated into any MHIAA ducted system the advanced Airzone zoning solution offers the ultimate level WI-FI of comfort by providing complete temperature control over each individual zone of your home or office. • Control your system using your smart device (iPhone, iPad, Android) or internet browser via to easy to use IntesisHome app. AIRZONE ZONE CONTROLLER • Control the set temperature, operation mode and fan speed. • Individual temperature and on/off control of up to 6 zones when used in • Control your system via your Google or Amazon smart speaker device. conjunction with Airzone zoning solution*. • Control your system using Voice Command. • Control the set temperature, operation mode and fan speed. • Set up ‘favourite’ scenes and activate them with a single tap. • Turn unoccupied zones off to save energy. • Set your system to respond to the weather, you arriving home, calendar • Control your system using your smart device (iPhone, iPad, Android) or events + more**. internet browser via easy to use Airzone app. • Receive instant notifications and email updates and create usage logs**. • Access timer and scheduling functions. *Requires MH-RC-WIFI-1B Wi-Fi adaptor (sold separately) for use with ducted systems. *Blueface controller shown (AZVAFBLUEFACECB) *Requires MH-AC-WIFI-1 Wi-Fi adaptor (sold separately) for use with bulkhead systems. **Airzone zoning solution includes motorised dampers, Airzone control board and webserver (sold separately) **In conjunction with IFTTT and other apps (must be downloaded separately). Some additional functions may not be available via IntesisHome app. In some applications, a 12V DC external power supply may be required for MH-RC-WI-FI-1B. Siri Controlling your device with IntesisHome app requires aforementioned Wi-Fi adaptors and working internet or Wi-Fi connection. Google Account required for use with Google devices. Features and services may change without notice. Google is a trademark of Google LLC. 10 11
12 MAINTENANCE & PREVENTION TIMERS COMFORT& CONVENIENCE ENERGY SAVING AIRFLOW 10 C FUNCTION Eco Pump Intake Speed Air Filter Function Hi Power Improved Operation Operation Operation Filter Sign Automatic Self-Clean Child Lock Operation* Operation* Outside Air Sleep Timer Home Leave Auto Restart Auto Return* On/Off Timer Built-in Drain Serviceability Weekly Timer Dry Operation Night Setback Automatic Fan Silent Operation Self-Diagnostics Peak-Cut Timer* Set Temperature Function Switch* any issues. maintenance. loss of power. limited space. turn on the unit. indoor temperature. reducing operation costs. to each time it is operated. the current room conditions. *Functions can only be enabled using RC-EXZ3A wired controller. your usual room usage on each day. centralised remote control is connected). DESCRIPTION avoiding the constant recycling of internal air. Alerts you to when the filter needs to be cleaned. temperature and adjusts the air flow automatically. ture is kept at around 10˚C, even while unoccupied. other allergens to provide you with a clean air function. tion while maintaining a comfortable room temperature. other settings. Useful for families with curious young children. cool temperatures. Perfect for when you’re away on holidays. noise levels, perfect for night time and an uninterrupted sleep. On-board microcomputer continuously monitors the room’s air The fan unit (comprised of impeller and motor) is easily accessible 30 and 240 mins that your unit will operate for before switching off. Provides clean fresh air into the room through the external air intake, period. Unit will then turn on and off at the specified times every day. from either the side or bottom of the unit and can be slid out for easy The air filter in the unit traps and removes airbor ne dust particles and flexibility with installation, offering a great solution for applications with Set your unit to turn on and off automatically on a weekly basis to suit Automatically restarts the unit in the same operating mode if it suffers a The built-in drain pump, which includes a lift of 600mm, allows greater the day, minimising energy consumption during peak billing times, thus preventing the growth of mould. Designed to be run regularly after use. Automatically selects the required heating or cooling function based on Provides 15mins of boosted power allowing you to quickly heat or cool Will maintain a moderate indoor temperature, avoiding extremely hot or Set your unit to turn on and off once, at specific times, within a 24 hour Allows you to program periods where the unit will operate with reduced Dries the indoor unit components by running the fan on ultra-low mode, two functions to operate automatically. (Note: this is not available when a This function lets you to preset the capacity limit during certain periods of Reduces humidity by removing moisture from the air without effecting the This function allows you to set a per-determined amount of time between Microcomputer automatically runs a diagnostic of the system in the event of a malfunction. This enables your authorised dealer to isolate and repair Allows you to program a preferred set temperature that the unit will return From the six available functions on the unit, this function allows you to set your home before returning to normal operation. Perfect for when you first Designed for the colder seasons, this function ensures the room tempera- Locks the remote control to prevent little ones from changing functions and The unit operates at a slightly reduced capacity to reduce power consump- Features and Functions FDU FDUA FDUM SRR PRODUCT SPECIFICATIONS FDUM & FDU SERIES FDUM50-60VH FDU71-140VH SRC50-60ZMXA-S FDCA71VNX FDCA100VN, FDC100VNP FDCA125-140VSX CAPACITY 5.0 KW 5.6 KW 7.1 KW 10.0KW 10.0 KW 12.5 KW 14.0 KW 12.5 KW 14.0 KW Set FDUM50ZMXAVH FDUM60 FDU71AVNXAVH FDU100VNP1VH FDU100AVNVF2 FDU125AVNXVH FDU140AVNXVH FDU125VSXVH FDU140AVSXVH Indoor FDUM50VH FDUM60VH FDU71VH FDU100VH FDU100VH FDU125VH FDU140VH FDU125VH FDU140VH Outdoor SRC50ZMXA-S SRC60ZMXA-S FDCA71VNXA FDC100VNP FDCA100VN FDCA125VNX FDCA140VNX FDC125VSX FDCA140VSX Power Source (Outdoor Unit) 1 Phase 240V 50Hz 3 Phase 380-415V 50Hz Cooling T1 5.0 (2.2-5.6) 5.6 (2.8-6.3) 7.1 (3.2-8.0) 10.0 (2.8-11.2) 10.0 (4.0-11.2) 12.5 (5.0-14.0) 14.0 (5.0-16.0) 12.5 (5.0-14.0) 14.0 (5.0-16.0) Nominal Capacity Heating H1 kW 5.4 (0.6-6.3) 6.7 (0.6-7.1) 8.0 (3.6-9.0) 11.2 (2.5-12.5) 11.2 (4.0-12.5) 14.0 (4.0-17.0) 16.0 (4.0-18.0) 14.0 (4.0-18.0) 16.0 (4.0-20.0) Range Heating H2 4.3 4.9 7.0 8.27 11.4 13.7 14.3 16.2 NA Cooling T1 1.56 1.75 2.20 3.00 2.92 3.60 4.40 3.60 4.40 Power Consumption kW Heating H1 1.70 2.00 2.20 2.93 3.20 3.90 4.54 3.90 4.54 Max Power Consumption kW 2.90 2.90 3.54 4.60 4.23 6.30 6.19 7.80 7.74 Cooling T1 7.00 7.80 9.80 13.20 13.10 16.00 19.50 6.10 6.70 *Operation Running Current A Heating H1 7.60 9.00 9.80 12.90 14.30 17.40 20.30 6.60 7.00 Data Inrush Current, Maximum Current A 5, 15 5, 15 5, 17 5, 22 5, 25 5, 29 5, 30 5, 18 5, 19 EER Cooling T1 3.21 3.20 3.23 3.33 3.42 3.47 3.18 3.47 3.18 COP Heating H1 3.18 3.35 3.64 3.82 3.50 3.59 3.52 3.59 3.52 Sound Power Level Outdoor 63 64 66 70 70 70 72 70 70 (JS C9612) P-Hi:37 Hi:32 P-Hi:36 Hi:31 P-Hi:38 Hi:33 P-Hi:44 Hi:38 P-Hi:44 Hi:38 P-Hi:45 Hi:40 P-Hi:47 Hi:40 P-Hi: 47 Hi: 40 P-Hi:47 Hi:40 Sound Pressure Level Indoor Me:29 Lo:26 Me:28 Lo:25 Me:29 Lo:25 Me:36 Lo:30 Me:36 Lo:30 Me:34 Lo:29 Me:35 Lo:30 Me: 35 Lo: 30 Me:35 Lo:30 dB(A) (JS C9612) Outdoor 50 54 51 57 49 50 49 48 49 Indoor 280x750x635 280x950x635 280x950x635 280x1370x740 280×1370×740 280×1370×740 280×1370×740 280×1370×740 280×1370×740 External Dimensions (HXWXD) mm Outdoor 640x800(+71)x290 640x800(+71)x290 750x880(+88)x340 845x970x370 845x970x370 1300x970x370 1300x970x370 1300x970x370 1300x970x370 Indoor 29 34 34 54 54 54 54 54 54 Net Weight Kg Outdoor 45 45 61 70 82 106 106 106 106 Supply Air Connection mm 170x680 170x880 170x880 170x1200 170x1200 170x1200 170x1200 170x1200 170x1200 Return Air Connection mm 200x660 200x860 200x860 235x1280 235x1280 235x1280 235x1280 235x1280 235x1280 External Static Pressure (Max) Pa 100 100 200 200 200 200 200 200 200 Indoor (Cooling) P-Hi: 217 Hi: 167 P-Hi:333 Hi:250 P-Hi: 400 Hi: 316 P-Hi:600 Hi:467 P-Hi: 600 Hi: 467 P-Hi:650 Hi:533 P-Hi:800 Hi:583 P-Hi:650 Hi:533 P-Hi:800 Hi:583 Airflow L/s Indoor (Heating) Me: 150 Lo: 133 Me:217 Lo:167 Me: 250 Lo: 166 Me:417 Lo:317 Me: 417 Lo: 317 Me:433 Lo:333 Me:467 Lo:367 Me:433 Lo:333 Me:467 Lo:367 Quantity Kg (R410A) 1.5 (R410A) 1.5 (R410A) 2.95 (R410A) 2.55 (R410A) 3.8 (R410A) 4.5 (R410A) 4.5 (R410A) 4.5 (R410A) 4.5 Refrigerant (Type, Amount, Pre-charge Length) Pre Charged To Pipe m 15 15 30 15 30 30 30 30 30 Length Liquid Line Ø6.35 Ø6.35 Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52 Refrigerant Piping mm Gas Line Ø12.7 Ø12.7 Ø15.88 Ø15.88 Ø15.88 Ø15.88 Ø15.88 Ø15.88 Ø15.88 Installation Connection Method Flare Connection Data Maximum Pipe Length (One Way) mm 30 30 50 30 50 100 100 100 100 30 ( O.U. above I.U. ) / 20 ( O.U. above I.U. ) / Max vertical height diff. between O.U. and I.U. 20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. ) 30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. ) 15 ( O.U. below I.U. ) 15 ( O.U. below I.U. ) Controller RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2 Motion Sensor (Optional) LB-KIT Demand response (AS4755) Yes Yes Yes No Yes Yes Yes No Yes * Operation data has been gathered in accordance with AS/NZS 3823 standards. For testing conditions please refer to Page 15 13
PRODUCT SPECIFICATIONS FDUA SERIES FDUA71VF/G FDUA100-160VF/G FDUA200VG FDCA71VNXA FDCA100VN, FDC100VNP FDCA125-140VNX, FDCA160-200VSA FDCA125-140VSX CAPACITY 7.1 KW 10.0 KW 10.0KW 12.5KW 14.0KW 12.5KW 14.0KW 16.0KW 20.0KW Set FDUA71AVNXVF FDUA100VNP1VF2 FDUA100AVNVF2 FDUA125AVNXVF FDUA140AVNXVF FDUA125VSXVF FDUA140AVSXVF FDUA160AVSAVF FDUA200AVSAVG Indoor FDUA71VF FDUA100VF2 FDUA100VF2 FDUA125VF FDUA140VF FDUA125VF FDUA140VF FDUA160VF FDUA200VG Outdoor FDCA71VNXA FDC100VNP FDCA100VN FDCA125VNX FDCA140VNX FDC125VSX FDCA140VSX FDCA160VSA FDCA200VSA Power Source (Outdoor Unit) 1 Phase 240V 50Hz 3 Phase 380-415V 50Hz Cooling T1 7.1 (3.2-8.0) 10.0 (2.8-11.2) 10.0 (4.0-11.2) 12.5 (5.0-14.0) 14.0 (5.0-16.0) 12.5 (5.0 - 14.0) 14.0 (5.0-16.0) 16.0 (6.9-20.0) 20.0 (6.9-28.0) Nominal Capacity Heating H1 kW 8.0 (3.6-9.0) 11.2 (2.5-12.5) 11.2 (4.0-12.5) 14.0 (4.0-17.0) 16.0 (4.0-18.0) 14.0 (4.0- 18.0) 16.0 (4.0-18.0) 18.0 (5.5-22.4) 22.4(5.5-31.5) Range Heating H2 7.0 8.04 10.0 14.0 15.0 16.0 14.0 15.0 22.0 Cooling T1 2.20 2.99 3.05 3.83 4.44 3.83 4.44 4.83 6.03 Power Consumption kW Heating H1 2.20 2.88 2.87 3.68 4.41 3.68 4.44 4.66 5.50 Max Power Consumption kW 3.54 4.60 4.02 6.13 5.77 7.66 7.26 12.70 13.70 Cooling T1 9.80 13.20 13.60 17.00 19.70 6.40 6.80 7.80 9.50 *Operation Running Current A Heating H1 9.80 12.90 12.70 16.30 19.60 6.20 6.70 7.60 8.70 Data Inrush Current, Maximum Current A 5, 17 5, 22 5, 25 5, 29 5, 30 5, 18 5, 19 5, 24 5, 27 EER Cooling T1 3.23 3.34 3.28 3.26 3.15 3.26 3.15 3.31 3.32 COP Heating H1 3.64 3.89 3.90 3.80 3.63 3.8 3.6 3.86 4.07 Sound Power Outdoor 66 70 70 70 72 70 70 73 73 Level (JS C9612) dB(A) P-Hi:38 Hi:33 Me:29 P-Hi:43 Hi:42 P-Hi:43 Hi:42 P-Hi:45 Hi:43 P-Hi:47 Hi:46 P-Hi : 47 Hi : 46 P-Hi:47 Hi:46 P-Hi:49 Hi:48 P-Hi:52 Hi:50 Sound Pressure Indoor Lo:25 Me:40 Lo:37 Me:40 Lo:37 Me:41 Lo:37 Me:43 Lo:40 Me : 43 Lo : 40 Me:43 Lo:40 Me:45 Lo:42 Me:47 Lo:45 Level (JS C9612) Outdoor 51 57 49 48 49 48 49 59 59 Indoor 280x950x635 398x1150x650 398x1150x650 398x1150x650 398x1150x650 398x1150x650 398x1150x650 398x1150x650 379x1600x893 External Dimensions (HXWXD) mm Outdoor 750x880(+88)x340 845x970x370 845x970x370 1300x970x370 1300x970x370 1300x970x370 1300x970x370 1505x970x370 1505x970x370 Indoor 34 52 52 52 52 52 52 52 89 Net Weight Kg Outdoor 61 70 81 106 106 106 106 143 143 Supply Air Connection mm 170x880 348x898 348x898 348x898 348x898 348x898 348x898 348x898 250x1450 Return Air Connection mm 200x860 348x898 348x898 348x898 348x898 348x898 348x898 348x898 250x1450 External Static Pressure (Max) Pa 200 200 200 200 200 200 200 200 200 Indoor (Cooling) P-Hi: 400 Hi: 316 P-Hi:650 Hi:600 P-Hi:650 Hi:600 P-Hi:717 Hi:650 P-Hi:850 Hi:800 P-Hi:717 Hi:650 P-Hi:850 Hi:800 P-Hi:850 Hi:800 P-Hi:1333 Hi:1200 Airflow L/s Indoor (Heating) Me: 250 Lo: 166 Me:550 Lo:483 Me:550 Lo:483 Me:600 Lo:500 Me:700 Lo:600 Me:600 Lo:500 Me:700 Lo:600 Me:700 Lo:600 Me:1067 Lo:933 Quantity Kg (R410A) 2.95 (R410A) 2.55 (R410A) 3.8 (R410A) 4.5 (R410A) 4.5 (R410A) 4.5 (R410A) 4.5 (R410A) 7.2 (R410A) 7.2 Refrigerant (Type, Amount, Pre-charge Length) Pre Charged To Pipe m 30 15 30 30 30 30 30 30 30 Length Liquid Line Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø12.7 Ø12.7 Refrigerant Piping mm Ø22.22 , Ø25.4 or Ø22.22 , Ø25.4 or Gas Line Ø15.88 Ø15.88 Ø15.88 Ø15.88 Ø15.88 Ø15.88 Ø15.88 Ø28.58 Ø28.58 Installation Connection Method Flare connection Liquid: Flare / Gas: Brazing Data Maximum Pipe Length (One Way) mm 50 30 50 100 100 100 100 **70 **70 30 ( O.U. above I.U. ) / 20 ( O.U. above I.U. ) / Max vertical height diff. between O.U. and I.U. 30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. ) 15 ( O.U. below I.U. ) 15 ( O.U. below I.U. ) Controller RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2 Safety Pan (Optional) UA-SP1-E UA-SP1-E UA-SP2-E UA-SP2-E UA-SP2-E UA-SP2-E UA-SP2-E UA-SP2-E N/A Motion Sensor (Optional) LB-KIT Demand response (AS4755) Yes No Yes Yes Yes No Yes Yes Yes * Operation data has been gathered in accordance with AS/NZS 3823 standards. For testing conditions please refer to Page 15. ** Maximum 70m (Gas piping:Ø25.4 or Ø28.58), Maximum 35m (Gas piping:Ø22.22) PRODUCT SPECIFICATIONS SRR SERIES SRR25-35ZS-W SRC25-35ZSA-W CAPACITY 2.5kW 3.5kW Indoor SRR25ZS-W SRR35ZS-W Outdoor SRC25ZSA-W SRC35ZSA-W Power Source (Outdoor Unit) 1 Phase 240V 50Hz Cooling T1 2.5 (0.9~3.4) 3.5 (0.9~4.1) Nominal Capacity (Range) Heating H1 kW 3.4 (0.9~4.8) 4.2 (1.0~5.2) Heating H2 3.55 4.1 Cooling T1 0.56 (0.20~0.90) 0.93 (0.19~1.26) Power Consumption kW Heating H1 0.75 (0.20~1.42) 1.01 (0.20~1.45) Maximum Power Consumption kW 1.65 1.65 Cooling T1 2.7 4.2 Running Current A *Operation Heating H1 3.5 4.5 Data Inrush Current, Maximum Current A 3.5, 9.0 4.5, 9.0 EER Cooling T1 4.46 4.16 COP Heating H1 4.53 3.04 Sound Power Level (JIS C9612) Outdoor dB (A) 60 62 Indoor 37-33-30-24 38-34-31-25 Sound Pressure Level (JIS C9612) dB(A) Outdoor 47 50 Indoor 200x750(+120)x500 200x750(+120)x500 External dimensions (HXWXD) mm Outdoor 540x780(+62)x290 540x780(+62)x290 Cooling (3.5) (3.5) Hot Heating (3.5) (3) Cooling (3) (3) Energy Label (GEMS 2019) Average Stars Heating (3) (2.5) Cooling (3) (3) Cold Heating (2.5) (2.5) Indoor 20.5 20.5 Net weight kg Outdoor 34.5 34.5 Cooling (Indoor) P-Hi:158 Hi:133 Me:108 Lo:75 P-Hi:167 Hi:142 Me:117 Lo:83 Airflow L/s Heating (Indoor) P-Hi:167 Hi:150 Me:133 Lo:100 P-Hi:175 Hi:158 Me:142 Lo:108 Quantity kg (R32) 0.78 (R32) 0.78 Refrigerant (Type, Amount, Pre-charge Length) Pre-Charged to Pipe m 15 15 Liquid line Ø6.35 Ø6.35 Refrigerant Piping mm Installation Data Gas line Ø9.52 Ø9.52 Connection Method Flare connection Maximum Pipe Length (One Way) m 20 Max Vertical Height Diff. Between O.U. and I.U. m 10 ( O.U. above I.U. ) / 10 ( O.U. below I.U. ) Standard accessories Polypropylene net x1 Optional parts Interface kit (SC-BIKN2-E) / Wi-Fi Kit Demand Response (AS4755) Yes *(1) The data is measured at the following conditions: (2) The air conditioner is manufactured and tested in conformity with the AS/NZS. Indoor Air Temperature Outdoor Air Temperature Item Standards (3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions. Operation DB WB DB WB (4) Select the breaker size according to applicable national standard. Cooling 27oC 19oC 35oC 24oC (5) The operation data indicate when the air-conditioner is operated at 240V 50Hz for 1 phase and 400V 50Hz for 3 phase AS/NZ 3823.2 Heating 20oC - 7oC 6oC 15
FDUM Series FDUM Series Model FDUM50VH Model FDUM60VH Symbol Content Symbol Content 200(Duct dimension ) 200(Duct dimension ) A Gas piping φ12.7 (1/2")(Flare ) Model 60 71 B Liquid piping φ6.35 (1/4")(Flare ) A Gas piping φ12.7 (1/2")(Flare ) φ15.88 (5/8")(Flare ) 65 660(Duct dimension ) 65 65 860(Duct dimension ) 65 B Liquid piping φ6.35 (1/4")(Flare ) φ9.52 (3/8")(Flare ) 46 200 200 200 46 C1 Drain piping VP25 (O.D.32 ) 46 4×200=800 46 C1 Drain piping VP25 ( O.D.32 ) 200 Drain hose piece Drain piping 41 41 Drain piping 31 31 Drain hose piece C2 VP20 (Accessory ) C2 VP20 (Accessory ) (Gravity drainage ) (Gravity drainage ) (Installed on site ) D Hole for wiring D Hole for wiring 170 170 (Installed on site ) E Suspension bolts (M10) E Suspension bolts (M10) Outside air opening Outside air opening F (φ150 )(Knock out ) F (φ150)(Knock out ) 31 for ducting 31 Return air duct for ducting 39 Return air duct 39 12-φ4 Air outlet opening Air outlet opening 14-φ4 (φ125)(Knock out ) Holes for G (φ125 )(Knock out ) G for ducting tapping screw for ducting Holes for tapping screw (450 ×450) H Inspection opening (450 ×450 ) H Inspection opening 786(Suspension bolts pitch ) Note(1) The model name label is attached on the lid of 986(Suspension bolts pitch ) Note(1) The model name label is attached on the lid of the control box. Hanger plate for 18 750 18 the control box. Hanger plate for 18 950 18 4-φ4 suspension bolt 4-φ4 284 4-φ4 suspension bolt 284 Holes for tapping screws Holes for 86 Holes for 4-φ4 152 262 tapping screws tapping screws Holes for 86 152 262 φ124 28 28 Control box tapping screws Control box φ124 F F 139 139 113 472 C1 472 69 C1 φ170 113 G 69 (Suspension bolts pitch ) G φ170 (Suspension bolts pitch ) φ170 □90 φ170 Hole B Hole □90 B F G 135 G 135 A F View M 58 View M A 58 (Max. drain lift ) 67 (Max. drain lift ) 30 635 30 67 30 635 30 170 (Duct dimension ) 170 (Duct dimension ) E 510 510 295 ~325 471 E 295 ~325 471 Air supply duct 413 Air supply duct 413 105 43 15 600 or less 105 43 15 or less 175 M 250 280 76 50 175 D M 250 600 280 76 50 D C2 467 55 680(Duct dimension ) 55 C2 467 55 880 (Duct dimension ) 55 Unit:mm Space for installation and service Space for installation and service Select either of two cases to keep space for installation and services. (Case 1 ) From side of unit (Case 2 ) From bottom of unit Select either of two cases to keep space for installation and services. (Case 1 ) From side of unit (Case 2 ) From bottom of unit or more Note (b) or more 20 Note (b) or more or more 100 100 20 Slab or more or more 1100 100 100 Slab 1300 Inspection 1000 or more or more H Ceiling or more 370 opening Inspection 20 600 1000 or more or more H Ceiling 150 - or more 200 620 370 opening 20 600 150 - Note (a) Note (c) 200 620 Fan unit Note (a) Note (c) 100 -200 Fan unit Notes (a) There must not be obstacle to draw 100 -200 out fan unit. For fan unit maintenance, Notes (a) There must not be obstacle to draw refer to page 106. out fan unit. For fan unit maintenance, (b) Install refrigerant pipes, refer to page 106. drain pipe,and wiring so as Note (a) (b) Install refrigerant pipes, not to cross marked area. drain pipe,and wiring so as (c) The case that pipes are installed to upper (bottom) of fan unit, Note (a) not to cross marked area. keep space of 60mm or more to upper (bottom) of unit. (c) The case that pipes are installed to upper (bottom ) of fan unit, keep space of 60mm or more to upper (bottom) of unit. 16 17
FDU Series (ii) FDU FDU Series Model FDU71VH Models FDU100VH, 125VH, 140VH Symbol Content 235(Duct dimension) 200(Duct dimension) A Gas piping φ 15.88(5/8")(Flare) B Liquid piping φ 9.52(3/8")(Flare) Symbol Content C1 Drain piping VP25(O.D.32) 65 740(Duct dimension) 185 Drain piping 64 1280(Duct dimension) 64 A Gas piping φ15.88(5/8")(Flare) C2 VP20 B Liquid piping φ9.52(3/8")(Flare) (Gravity drainage) 23.5 C1 Drain piping VP25(O.D.32) 41 D Hole for wiring Drain hose piece Drain piping E Suspension bolts (M10) C2 VP20 (Accessory) (Gravity drainage) Outside air opening F for ducting (Knock out) (Installed on site) D Hole for wiring Air outlet opening E Suspension bolts (M10) G (Knock out) Outside air opening for ducting F (Knock out) 39 21.5 Return air duct Drain hose piece Return air duct H Inspection opening (450×450) for ducting (Accessory) Air outlet opening (Installed on site) G (Knock out) for ducting H Inspection opening (450×450) 986(Suspension bolts pitch) 4-φ 4 4-φ 4 Hanger plate for 18 950 18 Holes for suspension bolt tapping screws 152 262 Holes for 1404 (Suspension bolts pitch) 284 tapping screws φ 124 18 1368 18 86 Hanger plate for 284 4-φ 4 4-φ 4 28 suspension bolt 86 Holes for 139 Control box tapping screws Holes for 152 285 F 28 tapping screws 113 Control box φ124 φ 170 (Suspension bolts pitch) φ 170 F 472 69 C1 90 G Hole 139 F G B (Suspension bolts pitch) 530 113 B View M G A φ170 135 φ170 A 71 C1 Hole 90 58 G F 180 600 or less (Max. drain lift) 67 30 635 30 View M 170 (Duct dimension) 510 E 59 295- 325 471 69 600 or less (Max. drain lift) Air supply duct 30 738 30 413 170 (Duct dimension) 635 105 E 43 15 295 325 468 Air supply duct 175 M 405 184.5 134.5 250 280 50 76 D 15 43 C2 467 M 250 280 50 92 55 880(Duct dimension) 55 D Unit:mm C2 467 Space for installation and service 104 1200(Duct dimension) 104 Select either of two cases to keep space for installation and services. (Case 1) From side of unit (Case 2) From bottom of unit Unit:mm or more Note(b) Space for installation and service or more or more 100 100 20 Select either of two cases to keep space for installation and services. Slab (Case 1) From side of unit (Case 2) From bottom of unit 1300 1000 or more Inspection Note(b) or more H or more or more or more or more Ceiling 100 100 20 opening 150- 370 600 200 20 Note(c) 620 Slab Note(a) 1720 Fan unit 100- 200 Inspection 1000 or more or more or more H Ceiling Notes(a)There must not be obstacle to draw 20 opening 600 Note(1)The model name label 200 370 150 out fan unit. For fan unit maintenance, 725 refer to page 71. is attached on the lid Note(a) Note(c) ( b) Install refrigerant pipes, of the control box. 100 200 Fan unit drain pipe, and wiring so as Note(a) not to cross marked area. Notes(a)There must not be obstacle to draw ( c) The case that pipes are installed to upper(bottom)of fan unit, out 2 fan units. For fan units maintenance, Note(1)The model name label keep space of 60mm or more to upper(bottom)of unit. refer to page 100. is attached on the lid ( b)Install refrigerant pipes, of the control box. drain pipe, and wiring so as not to cross marked area. Note(a) ( c)The case that pipes are installed to upper(bottom)of fan unit, keep space of 60mm or more to upper(bottom)of unit. 18 19
FDUA Series SRR Series 2. EXTERIOR DIMENSIONS (1) Indoor units (a) Ceiling concealed type (SRR) Models FDUA100VH, 125VH, 140H Models SRR25ZS-W, 35ZS-W 65 660(Inlet dimension) 65 (Duct dimension) Symbol Content 21 A Gas piping φ9.52(3/8") (Flare) 111 898 (Duct dimension) 181 B Liquid piping φ6.35(1/4") (Flare) VP25(I.D.25 , O.D.32) 160 D C1 Drain piping (Used with attached connector) (Inlet dimension) 26 Symbol Content Drain piping VP25(I.D.25 , O.D.32) A Gas piping Air Inlet C2 19 (Gravity drainage) (Used with attached connector) φ15.88(5/8")(Flare) B Liquid piping φ9.52(3/8")(Flare) 790(Suspension bolts pitch) D Hole for wiring φ25 x 2 348 C1 Drain piping VP25(I.D.25,O.D.32) E Suspension bolts (M10) 20 750 20 Drain piping F Inspection hole (450 x 450) (320 , x 770) C2 (Gravity drainage) VP25(I.D.25,O.D.32) 120 21 24 Return air duct Drain hose piece D Hole for wiring Control box Remote control signal receiver (Accessory) E Suspension bolts (M10) (Installed on site) F Inspection hole (450×450) Connector 68.7 (Accessory) 101 85 1185 (Suspension bolts pitch) 457 Hanger plate for (Installed on site) (Suspension bolts pitch) suspension bolt 17.5 1150 17.5 28 7.5 29.5 284 Remote control 30 86 signal receiver 28 (Cord length 1.8m) Control box 22 Hanger plate for 58 30 500 16 suspension bolt 59 413 472 165 370 C1 E (Duct dimension)(Suspension bolts pitch) 69 326 (Max. drain lift) Air outlet 235-265 C1 600 or less 35 B 150 55 105 A 168 37 99 50 200 (Outlet dimension) 61 74 40 650 40 380 E 65 660(Outlet dimension) 65 A B C2 or less (Max. drain lift) 531 295- 325 Wireless remote control Wired remote control Air supply duct 498 (Option) 458 24 15 167 172 215 248 Under 60 370 348 398 600 60 24 □120 19 D Unit:mm C2 Notes(1)The model name label is attached on the lid of the control box. 111 898 (Duct dimension) 181 506 (2)To connect the wired remote control, Unit:mm Space for installation and service the interface kit (SC-BIKN2-E) is required. Space for installation and service 320 Select either of two cases to keep space for installation and services. (Case 1) From side of unit (Case 2) Obstacle 100 From bottom of unit 150 or more Note(b) or more or more or more 100 100 20 Slab Rear-intake 150 or more Ceiling-return type 750 770 1500 or more F 1200 or more Ceiling Inspection or more 20 600 450 hole 150- 200 650 or more 200 1000 Note(a) 100 or more Note(c) 1000 or more Fan unit F Obstacle 750 100- 200 450 Notes (a) There must not be obstacle to draw Note(1)The model name label is attached out fan unit. For fan unit maintenance, on the lid of the control box. refer to page 94. (b) Install refrigerant pipes, Obstacle 100 drain pipe,and wiring so as Note(a) 450 not to cross marked area. View from top side of the unit (c) The case that pipes are installed to upper (bottom) of fan unit,keep space of 60mm or more to upper (bottom)of unit. 20 21
mhiaa.com.au ABN 92 133 980 275 Australia: Phone: 1300 138 007 NSW & Head Office Block E, 391 Park Road, Regents Park NSW 2143 Victoria 2/15 Howleys Road, Notting Hill VIC 3168 Brisbane 5/26 Flinders Parade, North Lakes QLD 4509 Townsville 1/37 Ross River Road, Mysterton QLD 4812 Western Australia 1/15-17 Capital Road, Malaga WA 6090 mhiheatpumps.co.nz G.S.T. 105-673-620 New Zealand: Phone: 0800 138 007 Auckland 698A Great South Road, Penrose, 1061 Mitsubishi Heavy Industries Air conditioners Australia, Pty. Ltd. Ducted Systems July 2020
You can also read