Ariston Thermo USA LLC Full Product Catalog 2021 - HTP
←
→
Page content transcription
If your browser does not render page correctly, please read the page content below
Ariston Thermo USA LLC Full Product Catalog 2021 ® A DIVISION OF Advanced Heating & Hot Water Systems
Your New Right Hand Man Search HTP Mobile in the App Store or Google Play or scan below to download today 2
HYDRONIC SPACE HEATING Elite XL Elite Premier Elite FT Pioneer Elite Ultra Elite Fire Tube Ultra Appliance Commercial Residential & Residential Type Boilers Commercial Boilers Space Heating Radiant Floor Yes Yes Yes Yes Yes Yes Fan Coil Yes Yes Yes Yes Yes Yes Base Board Max 180˚temp Snow Melt Yes Yes Yes Yes Yes Yes Heating & DHW w/ Indirect Tank or VWH w/ Indirect Tank Turndown Ratio 10:1 10:1 10:1 5:1 up to 1 1 : 1 up to 1 0 : 1 Cascading up to 8 Units Pool Heater w/ Indirect Tank ASME Yes Yes Yes Yes Mass Type Low Mass Low Mass Medium Mass High Mass Medium Mass Medium Mass Domestic (combi op- Hot Water VWH VWH tion) (combi option) Requires Primary/ Secondary Piping Configuration No Yes Yes No No No Integrated Buffer Tank – Hydronic Stabilization No No No 55 Gal. No No PAGE Number in the Catalog 6 8 10 12 14 19 COMBINATION HEATING Elite Ultra Elite Fire Tube Ultra Phoenix Plus Phoenix Phoenix LD Application Type Combi Units Gas Fired Water Heaters (with Air handler ) Radiant Floor Yes Yes Yes Yes Yes Fan Coil Yes Yes Yes Yes Yes Base Board Max 180˚temp Max 180˚temp Snow Melt Yes Yes Pool Heater w/ Indirect Tank w/ Indirect Tank ASME Yes Yes Co-Generation Heat Recovery Yes Yes Yes Domestic Hot Water Yes Yes Yes Yes Yes Requires Primary/ Secondary Piping Configuration No No No No No Integrated Buffer Tank – Hydronic Stabilization No No Yes Yes Yes PAGE Number in the Catalog 14 19 22 24 28 3
RESIDENTIAL WATER HEATING Phoenix Crossover Crossover Everlast Everlast Everlast Everlast Everlast SuperStor SuperStor Light Duty Wall Floor Whole Single & Point of Mini Tank Ultra Ultra Max Contender Home Multipoint Residential Use Appliance Gas Fired Appliance Type Gas Fired Hybrid Type Electric Tankless Electric Water Heaters Hydronic Indirects Storage W.H. Tank 316 L 316L 316L Titanium 316L 316L Glass Lined Stainless Tank Stainless Stainless Stainless Glass- Stainless Stainless w/ Anode Material Steel Material Lined Steel Steel Steel Steel Steel Rods Modulation 3 :1 10 : 1 2 :1 Modulation Heat 1 Durable 1 Durable 2 Durable 1 Durable 1 Durable 316L Smooth Heat Cupronickel Stainless Stainless Finned Exchanger / Titanium Copper Titanium Titanium Copper Stainless Enamel Exchanger Steel Steel Element Element Element Cupronickel Elements Elements Element Steel Coil Storage Storage Ultra SuperStor Tank Option Option Option Tank Option CB GL Combination Double Wall W/ Auxiliary With Air With Air Option Domestic & Space Heating Taps Handler Handler Exchanger Uniform Two Heat Energy Factor up to .90 up to .94 up to .89 Exchangers Option Btuh 76,000 199,000 100,000 Solar Option Yes Yes PAGE Number Kw Kw Kw Kw Kw in the Catalog 28 37 33 B tuh / kW 18 to 36 3.1 to 13 4.5 or 5.5 1.5 or 5 1.4 to 2 PAGE Number in the Catalog 39 40 47 49 51 53 55 57 COMMERCIAL WATER HEATING Phoenix Phoenix Elite XL Elite Premier Crossover Everlast Everlast Everlast Everlast Everlast Everlast Everlast Plus Phoenix Multi-Fit VWH VWH Whole Single & MD Com Commercial Home Multipoint 3 Element Medium Duty Light Duty Point of Mini Tank Commercial Commercial Use Appliance Gas Fired Volume Water Gas Fired Gas Fired Storage Water Heater Electric Tankless Electric Water Heaters Type Heaters Hybrid 316 L 316 L 316 L 316L 316L 316L 316L Titanium Tank Stainless Stainless Stainless Stainless Stainless Stainless Stainless Glass- Material Steel Steel Steel Steel Steel Steel Steel Lined Modulation up to 10 :1 5 :1 5 :1 10 :1 10 : 1 Heat Cupronickel Cupronickel Cupronickel 316 L 1 Durable 1 Durable 3 Durable 2 Durable 2 Durable 1 Durable 1 Durable Exchanger/ Stainless & Stainless & Stainless & Stainless Stainless Steel Titanium Copper Titanium Titanium Titanium Titanium Copper Steel Steel Steel Steel Elements Element Element Elements Elements Elements Element Element Storage Tank Requires Requires Storage Tank Option Storage Tank Multiple Heat Option Exchangers Combination Domestic & W/ Auxiliary W/ Auxiliary W/ Auxiliary Space Heating Taps Taps Taps Cascading up to 18 up to 8 Units Units Unit up to 180 º F High Temp. SA Models Tank up to Sanitation 160 º F Btuh Btuh Btuh Btuh Btuh Kw Btuh Kw Kw Kw Kw Kw Kw Btuh / kW 199,000 to 100,000 to 130,000 to 399,000 to 220,000 to 12.5 to 199,000 18 to 36 3.1 to 13 3 to 12 4.5 or 5.5 1.5 to 5 1.4 to 2 399,000 199,000 199,000 2,000,000 399, 000 18 PAGE Number in the Catalog 22 24 26 30 32 35 39 40 41 43 45 50 51 4
Large SSP Volume Solar Solar Tanks SOLAR TANKS Solar Electric Large Appliance with an Indirect Volume Type Back-up Solar 316L Tank Glass Lined Stainless Material Steel Steel ASME Yes Electric Electric or Heat with a Boiler Backup Exchanger Stinless Steel - Multiple Large Backup Coils Domestic Hot Water Yes Yes Limited Up to 1,000 Additional 10 Year Gallons Information Warranty Tank Size PAGE Number in the Catalog 64 64 STORAGE TANKS SuperStor SuperStor Large Ultra SS Glass Lined Volume Storage Storage Storage Appliance Storage Storage Storage Type Tank Tank Tank 316L Tank Glass Lined Glass Lined Stainless Material Steel Steel Steel ASME Available Yes Domestic Hot Water Yes Yes Yes 5 Sizes: 4 Sizes: 200 Gallons Additional 30 to 119 50 to 175 up to 5,695 Information Gallons Gallons Gallons PAGE Number in the Catalog 53 60 58 5
® COMMERCIAL HIGH EFFICIENCY CONDENSING BOILER Low Mass Boiler FEATURES: 4 pass heat exchanger with large internal circuits reduces pressure drop, allowing the unit to be used in variable flow system Durable 316L stainless steel construction pressure rated at 160 PSI bears the ASME Stamp (H) Combustion System - 10 to 1 turndown Three Pump Control - System, Boiler & DHW 7" High Resolution Touchscreen Display Cascade sequencing up to eight (8) boilers – Redundancy of operation (no downtime) – providing a much larger turndown ratio while increasing overall system efficiency and performance with unit runtime rotation 7 Sizes from HTP LINK - WiFi solution enables remote monitoring of the appliance and system 399,000 to 2,000,000 Btuh Direct vent up to 150 feet (1,500,000 to 2,000,000 Btuh Units) and up to 125 feet (399,000 to 1,000,000 97 % Thermal Efficiency Btuh Units) using PVC, CPVC, Polypropylene or Stainless Steel Ultra-Low NOx Operation Elite XL Applications: Radiant Floor • Fan Coil • Base Board • Snow Melt • DHW (w/ Indirect Tank) • Pool Heater (w Indirect Tank) • ASME 6 htproducts.com/elitexl
Model ELX- A B C D E F 400-500 40.7 41.0 26.0 17.9 35.0 4.1 650-1000 56.5 1500 66.5 60.8 31.8 39.2 44.8 51.2 2000 79.0 Model ELX- G H J K L M AA 399,000 to 400-1000 10.1 10.5 12.6 16.1 20.5 22.0 1,000,000 EE QQ 1500-2000 3.4 7.4 7.5 11.9 14.4 24.4 Btuh Units PP Model ELX- N O P Q R DD 400-1000 6.1 8.1 25.8 35.0 2.8* OO 1500-2000 31.8 4.6 6.5 22.7 39.1 BB RR CC FF GG NN HH JJ KK LL MM SCAQMD Rule 1146.2 A 1,500,000 F to 2,000,000 E Btuh Units D R Q G P B C H J O Heat Exchanger K 5 Year Limited Commercial Warranty Bears the ASME L “H” Stamp M N Model ELX-400FBN ELX-500FBN ELX-650FBN ELX-800FBN ELX-1000FBN ELX-1500FBN ELX-2000FBN Minimum / Maximum Input (Btu/Hr) 39,900 / 399,000 50,000 / 500,000 65,000 / 650,000 80,000 / 800,000 100,000 / 1,000,000 150,000 / 1,500,000 200,000 / 2,000,000 Heating Capacity (MBH) 387 485 630 776 970 1,455 1,940 Flue System Category IV, Sealed Combustion Direct Vent, Power Vent Minimum Combined Vent Run 10 feet 15 feet Maximum Combined Vent Run 4” (125 feet) 6” (125 feet) 8” (150 feet) Approved Exhaust Vent Materials PVC, CPVC, PP, Stainless Steel W 32.25 43.25 Packaging Dimensions H 49.625 64.25 (in Inches) D 48 64 76 86 Shipping Weight (lbs) 538 545 680 700 745 1400 1750 Gas Supply Pressure 3.5” to 14” WC (NG or LP) 3.5” to 10.5” WC (NG ONLY) Manifold Pressure Min / Max NG/LP: -0.08” WC NG: -0.07” WC 208/3PH WYE, Power Supply 120V 60 Hz, 21.3A 60Hz, 15A/Leg Customer Connection Board Fuse Amperage Ratings 2 Amps 5 Amps General Operating Conditions Ambient Temperature Range: 33 – 104oF (0.6 – 40oC); Product Approvals and Requirements: ANSI Z21.13 / CSA 4.9, CSD-1 ASME Code Ignition System Direct Electronic Spark Ignition / Flame Rectification Burner System Premixed Fuel Modulation / Stainless Steel Burner Gas Valve System Pneumatic Gas Valve Boiler Water Content (Gallons) 3.8 4.3 5.6 6.6 8.1 12.9 16.25 Minimum Flow Rate @ 20oF ∆T at Low Fire (GPM) 4 5 6.5 8 10 15 20 Boiler Setpoint Temperature Range 50 – 190oF / 32 - 190oF (with Outdoor Reset Curve) DHW Indirect Setpoint Temperature Range 70 – 185oF Heat Exchanger MAWP 160 Water Pressure (PSI) Pressure Relief Valve 50 Supply / Return 2” NPT 2 1/2” Flange Connection Sizes Gas Inlet 1” NPT 1 1/4” NPT 1 1/2” NPT 2” NPT Cabinet Powder Coated Galvaneal Steel Materials Heat Exchanger 316L Stainless Steel Water Tube 7
10 : 1 Turndown Premier Ratio LOW MASS Up to 96% Efficient Vents in inexpensive, easy-to-install PVC pipe, up to 200 combined feet State of the art control interface: a 2 line 20 character LCD control interface: Total System Control Impressive range: 7 models, ranging from 80,000 to 399,000 Btuh Floor standing or wall mount 12 year limited warranty 2016 316 L Stainless Steel Heat Exchanger Elite Premier Applications: Radiant Floor • Fan Coil • Base Board • Snow Melt • DHW (w/ Indirect Tank or VWH) • Pool Heater (w/ Indirect Tank) • ASME 8 htproducts.com/elitepremier
1 EXHAUST VENT CONNECTION 4 SYSTEM RETURN 7 GAS LINE CONNECTION 1COMBUSTION EXHAUST VENT CONNECTION 5 4SYSTEM SUPPLY SYSTEM WITH RETURN 7 GAS LINE CONNECTION 2 AIR INLET CONNECTION 8 DISPLAY/CONTROL PANEL INTEGRATED RELIEF VALVE 2 COMBUSTION AIR INLET CONNECTION 6 5 SYSTEM SUPPLY WITH 8 DISPLAY/CONTROL PANEL 3 ELECTRICAL CONNECTIONS CONDENSATE INTEGRATEDCONNECTION RELIEF VALVE 9 AIR RELEASE VENT 3 ELECTRICAL CONNECTIONS A 6 CONDENSATE CONNECTION 9 AIR RELEASE VENT B C A F 9 J D B N 1 C 8 9 K F J D N 1 8 K L M L 2 M 2 4 4 5 E G 5 E G TOP 3 TOP 3 6 LEFT SIDE H RIGHT SIDE 6 FRONT 7 LEFT SIDE H RIGHT SIDE FRONT 7 MODEL* A B C D E F G H J K L M N Shipping Weight EP-80 18.5” 11.5” 7.75” 4.25” 27” 14.5” 20” 4” 11.75” 7.38” 5.75” 9.75” 4” 108 lbs EP-110 18.5” 11.5” 7.75” 4.25” 27” 14.5” 20” 4” 11.75” 7.38” 5.75” 9.75” 4” 113 lbs EP-150 19.5” 12.5” 10.25” 2.50” 27” 14.5” 20” 3.75” 11.75” 7.38” 4.25” 8.25” 4” 126 lbs EP-220 26.5” 19.5” 15.50” 6.00” 24.25” 14.5” 20” 4.5” 11.75” 7.38” 4.25” 8.25” 4” 164 lbs 1 EXHAUST VENT CONNECTION 4 SYSTEM RETURN 7 CONDENSATE CONNECTION 1COMBUSTION EXHAUST VENT CONNECTION 5 4 SYSTEM RETURN 7 CONDENSATE CONNECTION 2 AIR INLET CONNECTION SYSTEM SUPPLY 8 GAS LINE CONNECTION 2 COMBUSTION AIR INLET CONNECTION 6 5 SYSTEM SUPPLY 8 GAS LINE CONNECTION 3 ELECTRICAL CONNECTIONS RELIEF VALVE 9 DISPLAY/CONTROL PANEL 3 A ELECTRICAL CONNECTIONS 6 RELIEF VALVE 9 DISPLAY/CONTROL PANEL B C A D B G 9 O E C K D G O M L E 9 K 1 M L 1 N 2 N 2 4 4 F 5 F 5 3 J 3 6 J 6 TOP 7 TOP 7 LEFT SIDE H RIGHT SIDE 8 FRONT LEFT SIDE H RIGHT SIDE 8 FRONT MODEL* A B C D E F G H J K L M N O Shipping Weight EP-299 24.75” 17.5” 14.5” 7.38” 3.25” 36.5” 14.5” 4.75” 21” 11” 7.88” 4.63” 9.5” 3.5” 211 lbs EP-301 24.75” 17.5” 14.5” 7.38” 3.25” 36.5” 14.5” 4.75” 21” 11” 7.88” 4.63” 9.5” 3.5” 211 lbs EP-399 31.75” 24.75” 21.5” 10.75” 3.75” 36” 14.5” 4.75” 21” 11” 7.88” 4.63” 9.5” 3.5” 256 lbs Model Btuh / Input Range Net Ratings (water) DOE Heating AFUE Supply/Return Exhaust /Air inlet Gas Connection EP-80 8,000 - 80,000 - 7, 700-77, 000 96.4 EP-110 11,000- 110,000 - 10,600-106,000 96.4 3/4” 1” 3” EP-150 15,000- 150,000 - 14,300-143,000 95.4 Heat Exchanger EP-220 22,000- 220,000 - 20,900-209,000 95.2 Bears the ASME “H” Stamp EP-299 30,000- 299,000 - 27,400-283,000 94.5 1-1/4” 1” EP-301 30,000- 301,000 251 Mbh 28,300-289,000 96.1** 4” EP-399 40,000- 399,000 335 Mbh 37,600-385,000 96.5 ** 1-1/2” * ”N”Denotes Natural Gas & “LP” Denotes Propane ** Thermal Efficiency (Not AFUE) 9
High Efficiency Medium Mass Boiler ® • Energy Star rated: up to 95.1% AFUE operating efficiency • Low NOx emission • Stainless steel fire tube heat exchanger • Outdoor reset lowers operating set point automatically • Unbeatable combined vent length of up to 150 ft. in 3” PVC pipe (EFT-285) • Room air intake • Down fire design, promotes self-cleaning of combustion system up to 97% Efficient • Increased thermal mass provides low 10 :1 Turndown Ratio pressure drop and eliminates short cycling • Built-in condensate collection system • Compatible with glycol based systems 2016 • Cascade up to 8 boilers Elite FT Applications: Radiant Floor • Fan Coil • Base Board • Snow Melt • DHW (w/ Indirect Tank) • Pool Heater (w/ Indirect Tank) • Retro Fit • ASME 10 htproducts.com/eliteft
Heating AFUE Model Capacity A B C D E F G H J K L M N O P Q /TE MBH EFT-285** 95.1 262 32 5/8” 20 5/8” 11 1/8” 6 7/8” 3 7/8” 2 1/4” 6” 14” 15 1/4” 11 1/8” 7 3/4” 6 7/8” 2 1/4” 13 3/8” 16 5/8” 20” EFT-399** 97.1* 367 36 3/8” 23 5/8” 13 5/8” 8 1/2” 4 3/4” 2 3/4” 7 3/8” 18 1/8” 18 3/4” 13 5/8” 9 3/4” 8 1/2” 2 3/4” 16 1/2” 19 1/4” 25 1/2” ** add PU to end of stock code to include a pump * Thermal Efficiency (Not AFUE) H INLET GAS LINE G H INLE H OUTLET INLET GAS LINE G 2016 F OUTLET G F E AIR INLET OUTLET F E D AIR INLET E D AIR INLET D J C J C A J K C A K Heat Exchanger A K Bears the ASME “H” Stamp L CONDENSATE M L DRAIN CONDENSA L M DRAIN N CONDENSATE DRAIN EXHAUST M NO EXHAUST N EXHAUST P O O Q P Top Vi e w P Q Q B B Side B Vi e w B o t to m Vi e w Model 285 399 STANDARD FEATURES Installation Indoor, Wall Hung, Fully Condensing - Up to 95.1% AFUE Minimum / Maximum Input (Btu/Hr) 28,500 / 285,000 39,900 / 399,000 - Modulating Burner Heating Capacity (MBH) 262 367* - 10:1 Turndown ratio - Venting Options Turndown Ratio 10 : 1 10 : 1 - Concentric Flue System Category IV, Sealed Combustion Direct Vent, Power Vent - 3” Pipe: Balanced Minimum Combined Vent Run 16 feet or Unbalanced (EFT-285) - 4” Pipe (EFT-399) Maximum Combined Vent Run 3” (150 feet) 4” (200 feet) - Limited 12 Year Warranty Approved Exhaust Vent Materials PVC, CPVC, PP, Stainless Steel - Wall Mounted Shipping Weight (lbs) 203 298 -Total System Control NG -The Elite FT is ASME Certified Gas Supply 3.5” to 14” WC Pressure LP Manifold Min / Max NG/LP: -0.01” WC Pressure INCLUDED IN THE BOX Power Supply 120V 60 Hz, 6.3A - Temperature and Pressure Gauge Ambient Temperature Range: 33 – 104oF (0.6 – 40oC) - Pressure Relief Valve 80 PSI General Operating Conditions - Indirect Sensor & Outdoor Sensor Product Approvals and Requirements: ANSI Z21.13 / CSA 4.9 - Intake PVC w/ Screens Ignition System Direct Electronic Spark Ignition / Flame Rectification - Exhaust PVC Coupling w/ Screens Burner System Premixed Fuel Modulation / Stainless Steel Metal Fiber Burner - Installation Manual Gas Valve System Air Ratio Valve - Warranty - Condensation Removal System W 20 25.5 Dimensions - Wall Mount H 32.6 36.4 (in Inches) D 20.6 23.6 Boiler Water Content (Gallons) 6.1 7.9 Minimum Flow Rate @ 30oF ∆T (GPM) 17.9 25.0 OPTIONAL EQUIPMENT Boiler Setpoint Temperature Range 50 – 190oF / 32 - 190oF (with Outdoor Reset Curve) - ModBus Adapter - 3”, 4”, 6” Stainless Steel Outside DHW Indirect Setpoint Temperature Range 70 – 180oF Termination Vent Kit Water Pressure Heat Exchanger MAWP 80 - 3” Concentric Vent Kit (PSI) Pressure Relief Valve 80 - 3” Polypro Vent Kit - 3” Polypro Pipe Control Panel / Main Controller LCD Display with LED Indicators / 926 SIT Control - U.L. 353 Compliant Low Water Connection Supply / Return 1 1/2” Copper SWT Cutoff w/ Manual Reset Sizes Gas Inlet 1” NPTF - Alarm System to Monitor Failures - PC Connection Kit Cabinet Powder Coated Galvaneal Steel Materials - Condensate Neutralizer Heat Exchanger S43932 Stainless Steel Fire Tube - System Sensor Flame Rectifier Probe, Dual Water Supply Temperature Sensor (199oF), Water - 3 Speed Pump with integrated Pressure Switch (Min. 10 PSI), Freeze Protection, Blocked Condensate Pressure Flow Check Safety Devices Switch, Condensate Trap with Float, Flue Temperature High Limit Sensor (210oF), - LP Conversion Kit Blocked Vent Pressure Switch, Optional UL353 Low Water Cut-Off Please refer to the Energy Star website or the rebate center on the HTP website for local rebates 11
Pioneer A Trailblazing Appliance that Installs with the Ease of a Mid-Efficiency Boiler but has the Performance of a High-Efficiency Product HIGH MASS • Modulation provides a 5 to 1 turndown ratio • Thermal mass in the stainless steel tank provides a buffer against cycling during low load conditions • Low maintenance & space saving design • Single loop installation: the heat exchanger is immersed in water and protected against "flashing" due to low flow condition • Up to 95% thermal efficiency • Retro-fit: ideal for replacement systems, minimize the changes to piping; no primary secondary piping needed • Room air intake, PVC and CPVC venting with combined vent lengths up to 200' in 3” pipe & up to 85' in 2" for the 100 & 130 models • Built in dirt & air separator • 12 year limited warranty Up to 95% Efficient • 5:1 Turndown Ratio • Single Loop Installation Pioneer Applications: Radiant Floor • Fan Coil • Base Board • Snow Melt • DHW (w/ Indirect Tank) • Pool Heater (w/ Indirect Tank) • Retro Fit • Buffer Tank 12 htproducts.com/pioneer
Dimensions & Specificat ions J J J PIONEER DIMENSIONS PIONEER PIONEER DIMENSIONS DIMENSIONS MODEL # MODEL MODEL GALLONS # # GALLONS AGALLONS B A CA B MODELS BD C ACE D DF B E G E F HC F G J G HDK H J L JE K K LF L G H J K L PHR100-55 PHR100-55 PHR100-55 PHR-100-55 PHR130-55 PHR130-55 PHR130-55 55 23" PHR-130-55 55 55 53" 23" 6-1/2" 23"53" 53" 8" 6-1/2" 6-1/2" 22" 8" 7-1/2" 8" 53" 22" 22" 8"7-1/2" 7-1/2" 6" PHR 160-55PHRPHR 160-55 160-55 23" 6.5" 8"34"8" 6"8" 45"6"34" 1-1/4" 34" 45" 45" 22" 1-1/4" 1-1/4" 7.5" 8" 6" 34" 45" 1.25" PHR-160-55 PHR199-55 PHR199-55 PHR199-55 PHR-199-55 Model PIONEER SPECIFICATIONS PIONEER PIONEER SPECIFICATIONS PHR-100-55 SPECIFICATIONS PHR-130-55 PHR-160-55 PHR-199-55 AIR AIR AIR Installation Indoor, Floor Model, Fully Condensing MODULATION MODULATION MODULATION INTAKE/EX INTAKE/EX INTAKE/EXSUPPLY/RETURN GAS GASGAS MODEL # MODEL MODEL # # SUPPLY/RETURN SUPPLY/RETURN SIZES SIZES AIR SIZES VENT AIR VENT AIR CONN VENT SHIPPING CONN CONNWEIGHT SHIPPING SHIPPING WEIGHT WEIGHT RANGE RANGE RANGE HAUST HAUST HAUST . . 94%. VENT SIZE VENTThermal SIZE SIZEEfficiency VENT 95% 95% 95% PHR100-55 PHR100-55 PHR100-55 33,000-100,000 33,000-100,000 33,000-100,000 2" 2"Input 2" Rate (Btuh) 35,000 ~ 100,000 35,000 ~ 130,000 40,000 ~ 160,000 40,000 ~ 199,000 PHR130-55 PHR130-55 PHR130-55 44,000- 130,000 44,000- 44,000- 130,000 2" 130,000 2" 2" 1-1/4" NPT 1-1/4" 1-1/4" NPT NPT 1/8" NPT 1/8"1/8" NPT 3/4" NPT 3/4" 175LBS 3/4" 175LBS 175LBS PHR 160-55PHRPHR 160-55 53,000-160,000 160-55 53,000-160,000 53,000-160,000 3" 3" Flue 3" System Sealed Combustion Direct Vent, Power Vent PHR199-55 PHR199-55 PHR199-55 66,000-199,000 66,000-199,000 66,000-199,000 3" 3" 3" Vent Run 2"(85 ft), 3"(200ft) Vents in PVC - CPVC - SS - ULC S636 Flexible LP-325-LPolypropylene LP-325-L Vent Liner LP-325-L PIONEER 07-22-10 07-22-10 DIMENSIONS 07-22-10 Weight 260 lbs. MODEL # GALLONS A B C D E F G Gas Supply Natural Gas 3.5''W.C ~ 14''W.C Pressure PHR100-55 Propane Gas 3.5''W.C ~ 14''W.C PHR130-55 Main Supply 120V55 60 Hz, 6A 23" 53" 6-1/2" 8" 22" 7-1/2" 8" Power Supply PHR 160-55 Maximum Power 160W PHR199-55 Ignition System Spark Ignition - Dual Flame Monitoring - Flame Stabilization Monitoring Burner System High-Grade Inconel Premix Burner PIONEER SPECIFICATIONS Gas System AIR Conversion Kit Retro-fit: ideal Fires on Natural or LP Gas with included MODEL # MODULATION INTAKE/EX SUPPLY/RETURN SIZES AIR VE Model Dimensions (W x H x D) RANGE W 23” x H 53” x HAUST D 34” for replacement VENT SIZE Heat Exchanger Copper Nickel Primary with 800 H and Copper Nickel Secondary Tube Construction PHR100-55 33,000-100,000 2" systems, minimize Water Pressure PHR130-55 44,000-12130,000 2" min - 30 max PSI 1-1/4" NPT 1/8" N PHR 160-55 53,000-160,000 3" the changes to Supply/Return PHR199-55 1 1/4'' FNPT 3" 66,000-199,000 Connection Sizes piping; no primary Gas Inlet 3/4'' NPT secondary piping Buffer Tank 55 Gallon - 304L Stainless Steel Warranty Limited 12 Year Residential Warranty needed STANDARD FEATURES INCLUDED IN THE BOX OPTIONAL EQUIPMENT - Modulating Burner - Pressure and Temperature - System Sensor - 5:1 Turndown Gauge - Indirect Tank Sensor Ratio - 30 PSI Temperature and - 3”, 4”, 6” Stainless Steel Outside Termination Vent Kit CAQMD Rule 1146.2 - Venting Options Pressure Relief Valve - 3” PVC Concentric Vent Kit - Room Air Intake - Intake PVC Tee w/ Screens TP Ma - Concentric - U.L. 353 Compliant Low Water Cutoff w/ Manual Reset •H a d - Exhaust PVC Coupling w/ - Flexible Vent Pipe - Alarm System to Monitor Failures eI n Amer i c Screens n Amer i c - Up to 200 combined ft. - PC Connection Kit - Installation Manual - Single Loop Installation - Condensate Neutralizer eI a - Outdoor Sensor • HT Mad - 12 Year Limited Warranty P 13
ULTRA Highly Efficient Condensing Boiler & Combi Units Medium Mass DURABLE HEATING - BOILER & COMBI UNITS Boiler Firing Rates: 85,000, 120,000, 150,000, 199,000 Btuh Combi Firing Rates: 120,000, 150,000, 199,000 Btuh Condensing technology with a new and patented XtraTech Stainless Steel Heat Exchanger, ensuring many years of reliable performance ABSOLUTE EFFICIENCY Up to 96% AFUE while using an outdoor sensor (included) Up to 11:1 turndown ratio limits short cycling and provides more ef- ficient energy consumption Built-in automatic bypass eliminates expensive primary / secondary piping Equipped with a built-in highly efficient ECM Pump WHISPER QUIET OPERATION Thanks to a pump and combustion fan with insulating panels EASY TO USE INTERFACE LCD display with digits, symbols, and an intuitive menu to easily set the desired temperature, activate functions, and even manage differ- ent heating zones ELU-85 - 120 Boiler and 120 - 150 Combi Model Shown COMBI BOILER: FULL COMFORT SETTING Domestic hot water preheat function for instant hot water SMART CONNECTIVITY WITH HTP LINK The Elite Ultra boiler is always at your fingertips with a WiFi gateway on board, allowing the boiler and its many system parameters to be monitored remotely Set up real-time service notifications and maintenance alerts to ensure that the unit is regularly monitored, overdue for maintenance, or if professional assistance is recommended EASY TO SERVICE WITH QUICK SNAP COMPONENT AND SENSOR CONNECTIONS FIFTEEN (15) YEAR LIMITED WARRANTY FLOOR AND WALL MOUNT MODELS AVAILABLE 14 htproducts.com/eliteultra
A Look Inside the ELU-85 - 120 Boiler and 120 - 150 Combi 1 25 1 25 24 24 23 23 1 2 25 21 25 22 22 3 24 3 24 4 4 5 5 23 23 62 21 62 21 7 22 20 7 2022 3 3 84 84 5 95 19 9 19 6 1821 6 1821 7 17 20 7 1720 10 8 8 11 9 16 19 11 1619 9 15 18 1518 12 12 17 14 1417 10 11 16 11 16 13 15 13 15 12 12 14 14 13 Combi Boiler 13 Boiler Combi Boiler Boiler 1. Pressure relief valve 15. Circulation pump 2. Air purge valve with auto air vent 26 3. Boiler outlet 16. DHW flow switch* temperature sensor 17. Water pressure switch 4. Air pressure switch 18. Modulating fan 5.1. Flue Pressure gas relief valve 15.Boiler 19. Circulation inlet pump 2. temperature Air purge valve sensor with auto temperature airsensor vent 26 6.3. Main Boilerheat outlet exchanger 17. Water 20. Frame pressure switch temperature 7. Flame detection sensor electrode 18. Modulating fan 21. Ignition electrode 4. Air 8 Silencerpressure switch 19.Spark 22. Boilergenerator inlet 9.5. Junction Flue gas box temperature sensor 23. Combustion temperature 10. DWH sensor heat exchanger* 20.analysis Frame test point 6. Condensate 11. Main heat exchanger trap 21.Air 24. Ignition intakeelectrode connection Flame 7. Gas 12. detection electrode valve 22. Spark generator 25. Exhaust vent 11 8 Silencer 13. Control panel 23.connection Combustion 9. C.H. 14. Junction circuitbox filter analysisvalve 26. Diverter test point *11. Condensate Applicable on combitrapunits only. 24. Air intake connection 11 12. Gas valve 25. Exhaust vent 13. Control panel connection 14. C.H. circuit filter 26. Diverter valve 15
Specifications Model ELU-85WBN ELU-120WBN ELU-120WCN ELU-150WCN Type Boiler Combi Installation Indoor, Wall Hung, Fully Condensing Space Heating Minimum / Maximum Input (Btu/Hr)1 9,400 / 85,000 13,200 / 120,000 11,200 / 106,000 13,200 / 120,000 Domestic Hot Water Minimum / Maximum Input (Btu/Hr)1 N/A N/A 11,200 / 114,000 13,200 / 150,000 DOE AFUE2 (%) 96 95 95.5 95 Heating Capacity1, 2 (MBH) 79 111 98 111 Net AHRI Rating, Water (MBH)2 69 97 85 97 35oF Rise N/A N/A 6.8 8.5 Hot Water Capacity 45oF Rise N/A N/A 5.3 6.6 77oF Rise N/A N/A 3.1 3.8 Flue System Category IV, Sealed Combustion Direct Vent, Power Vent Minimum - Maximum Exhaust Vent Run3 2” (6 - 100 feet), 3” (6 - 150 feet) Minimum - Maximum Intake Air Pipe Run3 2” (0 - 100 feet), 3” (0 - 150 feet) Approved Exhaust Vent Materials3 PVC, CPVC, PP, Stainless Steel Shipping Weight (lbs) 78 84 83 84 Gas Supply NG 3.5” to 10.5” WC Pressure LP 8” to 13” WC Power Supply 120V, 60 Hz, less than 12A Ambient Temperature Range: 33 – 104oF (0.6 – 40oC) General Operating Conditions Product Approvals and Requirements: ANSI Z21.13 / CSA 4.9 ELU E Ignition System Direct Electronic Spark Ignition / Flame Rectification Burner System Premixed Fuel Modulation / Stainless Steel Burner Gas Valve System Air Ratio Valve ELU ELUELU W 16” 3/64 Dimensions (in Inches) H Residential43”Condensing 5/8 GasResidential Boiler Condensin D 15” 1/8 Approx. Full Boiler Weight (lbs) 88.2 88.6 91 92.8 Boiler Water Content (Gallons) Installation 1.1 Installation Residential ResidentialCondensing Condensing ResidentialGas 1.2 Condensing GasBoiler 1.1Boiler Gas Boiler 1.2 Boiler Setpoint Temperature Range 68 – 122oF Low Temperature / 86 - 179oF High Temperature Commissioning DHW Indirect Setpoint Temperature Range Commissioning 104 – 149oF DHW Setpoint RangeInstallation Installation (Combi Models) Installation 97 – 140oF Heat Exchanger MAWP Maintenance Maintenance 50 Water Pressure (PSI) Commissioning Commissioning Commissioning Pressure Relief Valve 30 DHW Max Pressure N/A N/A 150 150 Parts Control Panel / Main Controller Parts Maintenance MaintenanceMaintenance AristonThermo LCD Display / AristonThermo GALEVO2 Control CH Supply / Return 1” Male Sweat with Adapter Connection DHW Inlet / Outlet Warranty Warranty 3/4” Male Sweat with Adapter Sizes Parts Parts Gas Inlet Parts 3/4” Male NPT Cabinet Painted Steel and Plastic Materials Warranty Warranty Heat Exchanger Warranty Type 441 Stainless Steel Water Tube Flame Rectifier Probe, Temperature Limit Control (190oF), Water Pressure Switch (Min. 8 PSI), Safety Devices Freeze Protection, Blocked Condensate Pressure Switch, Condensate Trap, Flue Temperature High Limit Sensor (210oF), Blocked Vent Pressure Switch Table 1 - Technical Specifications NOTES: DANGER DANGER 1 Listed Input and Output Ratings are at minimum vent lengths at an altitude of 0 - 2000 ft. Numbers will be lower with longer venting and/or altitudes greater than 2000 ft. Read all instructions in this manual before installing. PerformRead all in steps instructions the given in this manual before installing. Per 2 Ratings based on standard test procedures prescribed by the US Department of order. Energy. order. Failure Failure to do so could result in substantial property damage, severetopersonal do so could result in substantial property injury, or death. 3 The ELU requires a special venting system. Use only the vent materials and methods injury, or death. DANGER detailedDANGER DANGER in these installation instructions. WARNING WARNING Read Read order. allall order. instructions instructions Failure Failure to to dodo in in this soproduct so this Improper could manual could Read manual result order. all result before installation, inFailure warranty in 15 Year Limited Warranty before instructions installing. installing. substantial substantial and in this adjustment, Perform to do property cause so Perform property manual steps could damage, property result steps alteration, damage, damage, before in in thethe service,installing. given orgiven in substantial severe severe severe personal Performinstallation, Improper maintenance personal property product personal stepsvoid could damage, warranty injury, in theadjustment, severe given personal and cause or death. alteration, service, or m property damage, severe per injury, injury, or or death. death. Californiainjury, or death. Proposition 65 Warning: This product contains chemicals California Proposition known to the 65 Warning: This product contains State of California harm. to cause cancer, birth defects, or other 16 WARNING WARNING State of California to cause cancer, birth defects, or other reproductive WARNING NOTICE NOTICE Improper Improper installation, installation, adjustment, adjustment, Improper alteration, alteration, installation, service, service, adjustment, or or maintenance maintenance alteration, could could service, void void or maintenance could void
A Look Inside the ELU-150 - 199K BTU Combi/Boiler 24 1. Pressure relief valve 2. Air purge valve 1 25 3. Boiler outlet temperature sensor 4. Air pressure switch 23 5. Flue gas temperature sensor 2 6. Main heat exchanger 5 7. Flame detection electrode 8 Silencer 9. Junction box 3 22 10. DHW Heat Exchanger (Combi Models Only) 6 11. Condensate trap 21 7 12. Gas valve 13. Control panel 15. Circulation Pump 9 19 16. DHW Flow Sensor (Combi Models Only) 17. Water pressure switch 8 18. Modulating Fan 20 19. Boiler inlet temperature sensor 18 26 20. Frame 11 21. Ignition electrode 10 22. Spark generator 15 23. Combustion Analysis Test Point 12 13 24. Air intake connection 17 25. Exhaust vent connection 26. Diverter valve 16 You're in Control - Wherever You Are* With HTP Link, you and trusted service personnel can: • Remotely view boiler parameters and status, ensuring proper operation and maximum efficiency. • Receive boiler text and e-mail updates, alerting service personnel of possible issues. • Access the boiler and troubleshoot issues without having to be onsite, reducing costly service calls. ELU-150 - 199 Boiler and 199 Combi Model Shown ELU-150 - 199 Boiler and 199 Combi Floor Mount ("FLK") Model Shown *HTP Link Available on All Models 17
Specifications - ELU-150 - 199K BTU Combi/Boiler Model ELU-150WBN ELU-150WBNFLK ELU-199WBN ELU-199WBNFLK ELU-199WCN ELU-199WCNFLK Type Boiler Combi Installation Indoor, Wall Hung, Fully Condensing NG 19,700 / 197,000 NG 19,700 / 197,000 Minimum / Maximum Input (Btu/Hr)1 15,000 / 150,000 LP 19,200 / 192,000 LP 19,200 / 192,000 DOE AFUE2 (%) 95 95 95 Heating Capacity1, 2 (MBH) 139 184 184 Net AHRI Rating, Water (MBH)2 121 160 160 35oF Rise N/A N/A 10.5 Hot Water Capacity 45oF Rise N/A N/A 8.2 77oF Rise N/A N/A 4.8 Flue System Category IV, Sealed Combustion Direct Vent, Power Vent Minimum - Maximum Exhaust Vent Run3 2” (6 - 100 feet) / 3” (6 - 150 feet) 3” (6 - 150 feet) Minimum - Maximum Intake Air Pipe Run3 2” (0 - 100 feet) / 3” (0 - 150 feet) 3” (0 - 150 feet) Approved Exhaust Vent Materials3 PVC, CPVC, PP, Stainless Steel Shipping Weight (lbs) 115 150 125 160 130 165 Gas Supply NG 3.5” to 10.5” WC Pressure LP 8” to 13” WC Power Supply 120V, 60 Hz, less than 12A ELU Ambient Temperature Range: 33 – 104oF (0.6 – 40oC) General Operating Conditions Product Approvals and Requirements: ANSI Z21.13 / CSA 4.9 Ignition System Direct Electronic Spark Ignition / Flame Rectification ELU ELU ELU Burner System Premixed Fuel Modulation / Stainless Steel Burner Gas Valve System Air Ratio Valve Residential Residential Condens Condensing Gas Boiler W 19.75” 21.65" 19.75” 21.65" 19.75” 21.65" Dimensions H 38.25” 50.97" 38.25” 50.97" 38.25” 50.97" (in Inches) D Installation 18.5” 20.09" ResidentialInstallation Residential Condensing Condensing18.5” Residential Gas GasBoiler Condensing Boiler 20.09" Gas Boiler 20.09" 18.5” Approx. Full Boiler Weight (lbs) 115 150 130 165 135 170 Boiler Water Content (Gallons) Commissioning 2 Commissioning2.7 Boiler Setpoint Temperature Range Installation Installation Installation 68 – 122oF Low Temperature / 86 - 179oF High Temperature o DHW Indirect Setpoint Temperature Range 104 – 149 F Maintenance Maintenance DHW Setpoint Range (CombiCommissioning Commissioning Models) Commissioning o 97 – 140 F Heat Exchanger MAWP 50 Water Pressure Parts Pressure Relief Valve Parts30 (PSI) Maintenance Maintenance Maintenance DHW Max Pressure N/A N/A 150 Control Panel / Main Controller Warranty Warranty AristonThermo LCD Display / AristonThermo GALEVO2 Control Parts Parts CH Supply / Return Parts 1 1/4” Male NPT Connection DHW Inlet / Outlet 3/4” Male NPT Sizes Warranty Warranty Gas Inlet Warranty 3/4” Male NPT Cabinet Painted and Galvanized Steel Materials Heat Exchanger Type 441 Stainless Steel Water Tube Flame Rectifier Probe, Temperature Limit Control (190oF), Water Pressure Switch (Min. 8 PSI), Freeze Protection, Safety Devices Condensate Trap, Flue Temperature High Limit Sensor (210oF) DANGER DANGER Table 2 - Technical Specifications NOTES: 1 Read all instructions in this manual before installing. Perform steps inRead all instructions in this manual before installing. P the given Listed Input and Output Ratings are at minimum vent lengths at an altitude of 0 - 2000 ft. Numbers will be lower with longer venting and/or altitudes greater than 2000 ft. 2 order.personal order. Failure to do so could result in substantial property damage, severe Failure to do so could result in substantial prope Ratings based on standard test procedures prescribed by the US Department of Energy. injury, or death. 3 injury, or death. The ELU requires a special venting system. Use only the vent materials and methods detailed DANGER DANGER in these installation instructions. DANGER WARNING WARNING Read Readall order. allinstructions instructions order.Failure ininthis Improper Failuretotoproduct do doso this socould could manual manualbefore installation, result result warranty before adjustment, ininsubstantial and order. substantial cause 15 Year Limited Warranty Readinstalling. all installing. instructions Failure Perform Perform property property property in service, alteration, todamage, do so this steps damage, steps damage, could manual ininorthe result severe severesevere thebefore given given installing. maintenance inpersonal substantial personal personal couldPerform Improper orproperty injury,product death. steps inadjustment, installation, void damage, warranty the given alteration, service, o andsevere causepersonal property damage, severe injury, injury,orordeath. death.California Proposition 65 injury, or death. Warning: This product contains chemicals known California Proposition 65 Warning: This product contain to the State of California to cause cancer, birth defects, or other reproductive State harm.of California to cause cancer, birth defects, or oth WARNING WARNING WARNING In accordance with our company policy of ongoing product improvement, HTP reserves the right to make changes without prior notice. • Preliminary product specifications NOTICE NOTICE Improper Improperinstallation, installation,adjustment, adjustment,alteration, alteration, Improper service, service, installation, orormaintenance maintenance adjustment, could could alteration, void void service, or maintenance could void product productwarranty warranty and Theand cause causeproperty property manufacturer damage, product damage, reserves thewarranty severe severe right topersonal personal and cause make injury, injury, property product orordeath. death. changes damage, severe or updates personal injury, The manufacturer without or death. reserves the right to make product c 18 California CaliforniaProposition Proposition notice 6565Warning: and Warning: This will not beThis California product heldproduct liablecontains Proposition contains for chemicals chemicals 65 Warning: typographical known known errors This in totoproduct the the notice literature. contains andchemicals will not beknown to thefor typographical erro held liable State StateofofCalifornia Californiatotocause causecancer, cancer,birth birth State defects, defects, of California ororother othertoreproductive reproductive cause cancer, harm. harm. birth defects, or other reproductive harm. The surfaces of these products contacted by potable (consumable) waterThe surfaces contain less of these products contacted by potable (con
Fire Tube ULTRA Highly Efficient Condensing Boiler & Combi Units ® Features DURABLE HEATING - BOILER & COMBI UNITS Boiler Firing Rates: 85,000, 110,000, 150,000, 199,000 Btuh Combi Firing Rates: 110,000, 150,000, 199,000 Btuh Vertical down fired Stainless Steel Heat Exchanger for exceptional efficiency, low pressure drop, and durable performance ABSOLUTE EFFICIENCY Up to 96% AFUE while using an outdoor sensor (included) 10:1 turndown ratio limits short cycling and provides more efficient energy consumption Built-in automatic bypass eliminates expensive primary / secondary piping Equipped with a built-in highly efficient ECM Pump WHISPER QUIET OPERATION Thanks to a pump and combustion fan with insulating panels EASY TO USE INTERFACE LCD display with digits, symbols, and an intuitive menu to easily set the de- sired temperature, activate functions, and manage different heating zones COMBI BOILER: FULL COMFORT SETTING Domestic hot water preheat function for instant hot water SMART CONNECTIVITY WITH HTP LINK The Elite Ultra boiler is always at your fingertips with a WiFi gateway on board, allowing the boiler and its many system parameters to be monitored remotely Set up real-time service notifications and maintenance alerts to ensure that the unit is regularly monitored, overdue for main- tenance, or if professional assistance is recommended EASY TO SERVICE WITH QUICK SNAP COMPONENT AND SENSOR CONNECTIONS ASSE 1017 & 1070 CERTIFED THERMOSTATIC MIXING VALVE INCLUDED WITH COMBI UNITS FIFTEEN (15) YEAR LIMITED WARRANTY 19
A Look Inside the EFTU-85 - 199K BTU Combi/Boiler 24 25 1. Pressure relief valve 1 2. Air purge valve 3. Boiler outlet temperature sensor 23 4. Air pressure switch 22 2 5. Flue gas temperature sensor 6. Main heat exchanger 18 7. Flame detection electrode 7 5 8 Silencer 21 4 9. Junction box 10. DHW Heat Exchanger (Combi Models Only) 3 12 11. Condensate trap 8 12. Gas valve 13. Control panel 20 15. Circulation Pump 6 16. DHW Flow Sensor (Combi Models Only) 17. Water pressure switch 9 18. Modulating Fan 19. Boiler inlet temperature sensor 20. Frame 19 21. Ignition electrode 26 22. Spark generator 15 10 23. Combustion Analysis Test Point 11 24. Air intake connection 25. Exhaust vent connection 13 17 26. Diverter valve 16 Vertical Fire Tube Heat Exchanger • Features robust SA-240 S43932 Chro- mium stainless steel • Down-Fired design resists combustion chamber fouling better than other heat Up to 96 exchanger types • Resists scale build-up and magnetite formation, increasing heat exchanger life and reducing maintenance • Innovative dimpled tubes extract more heat while remaining compact, without the need for inserts that degrade over time 20
Specifications Model EFTU-85WBN EFTU-110WBN EFTU-150WBN EFTU-199WBN EFTU-110WCN EFTU-150WCN EFTU-199WCN Type Boiler Boiler Boiler Boiler Combi Combi Combi Installation Indoor, Wall Hung, Fully Condensing 8,500 / 11,000 / 15,000 / 19,900 / 11,000 / 15,000 / 19,900 / Minimum / Maximum Input (Btu/Hr)1 85,000 110,000 150,000 199,000 110,000 150,000 199,000 DOE AFUE2 (%) 96 95 95 95 95 95 95 Heating Capacity1, 2 (MBH) 79 101 138 184 101 138 184 Net AHRI Rating, Water (MBH)2 69 88 120 160 88 120 160 35oF Rise 5.8 7.9 10.5 Hot Water Capa- 45oF Rise N/A N/A N/A N/A 4.5 6.1 8.2 city 77oF Rise 2.6 3.6 4.8 Flue System Category IV, Sealed Combustion Direct Vent, Power Vent Minimum - Maximum Exhaust Vent Run3 2” (6 - 100 feet), 3” (6 - 150 feet) 3” (6 - 150 feet) 2” (6 - 100 feet), 3” (6 - 150 feet) 3” (6 - 150 feet) Minimum - Maximum Intake Air Pipe Run3 2” (0 - 100 feet), 3” (0 - 150 feet) 3” (0 - 150 feet) 2” (0 - 100 feet), 3” (0 - 150 feet) 3” (0 - 150 feet) Approved Exhaust Vent Materials3 PVC, CPVC, PP, Stainless Steel Shipping Weight (lbs) 110 110 120 131 110 121 132 Gas Supply NG 3.5” to 10.5” WC Pressure LP 8” to 13” WC Power Supply 120V, 60 Hz, less than 12A Ambient Temperature Range: 33 – 104oF (0.6 – 40oC) General Operating Conditions ELU Product Approvals and Requirements: ANSI Z21.13 / CSA 4.9 Ignition System Direct Electronic Spark Ignition / Flame Rectification Burner System Premixed Fuel Modulation / Stainless Steel Burner Gas Valve System Air Ratio Valve ELU ELU ELU W 19.75 Dimensions H Residential 38.25 Residential Condens Condensing Gas Boiler (in Inches) D 17 18.5 17 18.5 Approx. Full Boiler Weight (lbs) 107 107 122 139.5 107 128.5 140.5 Installation Residential Residential Installation Condensing Condensing Residential Gas Gas Boiler Condensing Boiler2.1 Gas 2.8 Boiler Boiler Water Content (Gallons) 1.4 1.4 2.0 2.8 1.5 Boiler Setpoint Temperature Range 68 – 122oF Low Temperature / 86 - 179oF High Temperature DHW Indirect Setpoint Temperature Commissioning Commissioning Range Installation Installation Installation 104 – 149oF DHW Setpoint Range (Combi Models) Maintenance Maintenance 97 – 149oF Commissioning Commissioning Heat Exchanger MAWP Commissioning 50 Water Pressure Pressure Relief Valve 30 (PSI) DHW Max Pressure Parts Parts Maintenance Maintenance N/A Maintenance N/A N/A N/A 150 150 150 Control Panel / Main Controller AristonThermo LCD Display / AristonThermo GALEVO2 Control CH Supply / Return Warranty Warranty 1 1/4” Male NPT Connection Parts Parts DHW Inlet / Outlet Parts 3/4” Male NPT Sizes Gas Inlet 3/4” Male NPT Materials Cabinet Warranty Warranty Warranty Painted Steel Heat Exchanger SA-240-S43932 Stainless Steel Water Tube Flame Rectifier Probe, Temperature Limit Control (190oF), Water Pressure Switch (Min. 8 PSI), Freeze Protection, Safety Devices Blocked Condensate Pressure Switch, Condensate Trap, Flue Temperature High Limit Sensor (210oF), Blocked Vent Pressure Switch Table 3 - Technical Specifications DANGER DANGER NOTES: 1 Listed Input and Output Ratings are at minimum vent lengths at an altitude of 0 - 2000 ft. Numbers will be lower Read all instructions with in this longer manual venting before and/or installing. altitudes Perform steps ingreater Read than 2000 in all instructions the given ft.this manual before installing. P 2 Ratings based on standard test procedures prescribed by the US Department of Energy. order. Failure to do so could result in substantial property damage, order.personal severe Failure to do so could result in substantial prope 3 The EFTUrequires a special venting system. Use only the vent materials and methods detailed in these injury, installation instructions. or death. injury, or death. DANGER DANGER DANGER WARNING WARNING Read Readall order. allinstructions instructions order.Failure ininthis Improper Failuretotoproduct do doso this socould could manual manualbefore installation, result result warranty before adjustment, ininsubstantial and order. substantial cause 15 Year Limited Warranty Readinstalling. all installing. instructions Failure Perform Perform property propertyproperty in service, alteration, todamage, do so this steps damage, steps damage, could manual ininorthe result severe severesevere thebefore given given installing. maintenance inpersonal substantial personal personal couldPerform Improper orproperty injury,product death. steps inadjustment, installation, void damage, warranty the given alteration, service, o andsevere causepersonal property damage, severe p injury, injury,orordeath. death.California Proposition 65 injury, or death. Warning: This product contains chemicals known California Proposition 65 Warning: This product contain to the State of California to cause cancer, birth defects, or other reproductive State harm.of California to cause cancer, birth defects, or oth WARNING WARNING WARNING In accordance with our company policy of ongoing product improvement, HTP reserves the right to make changes without prior notice. • Preliminary product NOTICEspecifications NOTICE Improper Improperinstallation, installation,adjustment, adjustment,alteration, alteration, Improper service, service, installation, orormaintenance maintenance adjustment, could could alteration, void void service, or maintenance could void product productwarranty warranty and Theand cause causeproperty property manufacturer damage, product damage, reserves thewarranty severe severe right topersonal personal and cause make injury, injury, property product orordeath. death. changes damage, severe or updates personal injury, The manufacturer without or death. reserves the right to make product c 21 California CaliforniaProposition Proposition notice 6565Warning: and Warning: This will not beThis California product heldproduct liablecontains Proposition contains for chemicals chemicals 65 Warning: typographical known known errors This in totoproduct the the notice literature. contains andchemicals will not beknown to thefor typographical error held liable State StateofofCalifornia Californiatotocause causecancer, cancer,birth birth State defects, defects, of California ororother othertoreproductive reproductive cause cancer, harm. harm. birth defects, or other reproductive harm.
Phoenix Plus ® High Efficiency Stainless Steel Indoor / Outdoor Gas Fired Water Heater Super Durable 10:1 • 316 L stainless steel tank, (lightweight) longer service life Up to • Heavy duty outdoor enclosure protects the internal components including Turndown Ratio the built-in condensate trap • 2 hybrid cupronickel / stainless steel heat exchangers * 4 Btuh Sizes • 119 gallon storage: reduced cycling, adds to component life • No additional storage tanks needed 199K * • 260 K Super Efficient 320 K • 399K • Up to 95% thermal efficiency • Best 1st hour output and recovery • Load-matching modulation • Up to 10:1 turndown ratio: Built-in Redundancy (The 199K model has a 5:1 turndown ratio) modulates down to 10% of input (Dual Combustion System) capacity optimizes energy and reduces cycling, increasing efficiency Small Footprint • Recirculation port on the top section provides additional efficiency Indoor / Outdoor • Controls can be adjusted to increase efficiency by staging each Installation combustion system * • Low NOx combustion system meets the most stringent standards • Power vent or direct vent options TP Ma •H d a eI n Amer i c n Amer i c eI a SCAQMD Rule 1146.2 • HT Mad P *PHP199-119: features one control panel and one combustion system; cannot be staged; 199K Model: 5:1 turndown ratio 22 htproducts.com/phoenixplus
Specifications HOT OUTLET STANDARD FEATURES WHAT’S IN THE BOX HOT OUTLET - Up to 95% Thermal Efficiency - Brass Tee and Bushing - 2 Modulating Burners - Up to 10 :1 Turndown Ratio - Temperature and Pressure Relief Valve (PHP199-199: 1 Burner; 199K model: 5:1 Turndown Ratio) - Installation Manual & Warranty - Vents in PVC, CPVC, Stainless Steel, ULC S636 - LP Conversion Kit (Natural Gas Models Only) - Spark ignition OPTIONAL EQUIPMENT - Dual flame monitoring (Spark & Flame probe) - 3” PVC Concentric Vent Kit - Flame stabilization monitoring (for the PHP199-199 Model) - Integrated Control System INTAKE EXHAUST 24.4” - 3”& 4” Stainless Steel Outside INTAKE EXHAUST 24.4” 5.5” - Pressure relief pre-piped Termination Vent Kits 5.5” - Built-in low water cut-off probe - Condensate Neutralizer - Limited 3 Year Commercial Warranty - Condensate Pump - PC Connection Cable w/ Software 21” 21” 38” 32” 38” 32” AUXILLARY 85” (77” for the PHP199-199) AUXILLARY 85” (77” for the PHP199-199) (RECIRC PORT) (RECIRC PORT) ELECTRICAL ELECTRICAL 58.75” (49” for the PHP199-199) 58.75” (49” for the PHP199-199) GAS GAS 42.125” 42.125” COLD INLET COLD INLET CONDENSATE CONDENSATE 9.75” 9.75” GPH at First # of Btuh Input Air Gas Gallon Inlet/ Relief Shipping Thermal Model Aux 100˚ F Hour Combustion Modulation Intake Line Capacity Outlet Valve Weight Efficiency Rise Rating Systems PHP199-119 40k – 199k Btuh 3” 475 LBS 232 315 1 95% PHP260-119 35k – 260k Btuh ¾” 119 1 ½” NPT 1” NPT 1” NPT 555 LBS 303 386 2 94% 4” PHP320-119 40k – 320k Btuh 575 LBS 372 455 2 94% PHP399-119 40k – 399k Btuh 575 LBS 464 574 2 95% 23
The Phoenix ® 316 L Stainless Steel Tank Super Durable: Super Efficient: • 316L stainless steel tank • up to 96% efficiency • Hybrid cupronickel /stainless • Load-matching modulation steel heat exchanger • Outdoor sensor auto adjusts • Reduced cycling adds for maximum efficiency to component life • 2” foam insulation • Venting: PVC/ CPVC • up to ½°F/hr standby loss • 5:1 turndown ratio Power vent or direct power vent options Sanitizer Options Available Phoenix Sanitizer: The Phoenix line offers a high temp sanitation tank for those need to be clean applications. Great for use in restaurants, breweries, wineries, dairies and more. Up to 96% Efficient PHOENIX WATER HEATER AND SANITIZER BOOSTER SPECIFICATIONS Btuh Recovery at Gallon Inlet/ Shipping MODEL (w/ Mod) 100 0 F. Rise Capacity Outlet Size Weight PH100-55 35,000 - 100,000 115 55 1” NPT 175 LBS PH130-55 35,000 - 130,000 148 55 1” NPT 175 LBS PH160-55 40,000 - 160,000 184 55 1” NPT 175 LBS PH199-55 40,000 - 199,000 229 55 1” NPT 175 LBS PH100-80 35,000 - 100,000 116 80 1.5” NPT 235 LBS PH130-80 35,000 - 130,000 150 80 1.5” NPT 235 LBS PH160-80 40,000 - 160,000 184 80 1.5” NPT 235 LBS PH199-80 40,000 - 199,000 229 80 1.5” NPT 235 LBS PH100-119 35,000 - 100,000 117 119 1.5” NPT 405 LBS PH130-119 35,000 - 130,000 152 119 1.5” NPT 405 LBS PH160-119 40,000 - 160,000 184 119 1.5” NPT 405 LBS PH199-119 40,000 - 199,000 230 119 1.5” NPT 405 LBS PH199-55SA (184 F) 40,000 - 199,000 229 55 1” NPT 175 LBS Note: All units are compatible with natural gas or liquid propane, but must be specified upon placing an order. 24 htproducts.com/phoenix
The Phoenix Dimensions & Specifications LEFT SIDE FRONT VIEW AUX. CONNECTION AUX. CONNECTION q h f g s q ? h r f h g c s d ? r h c d TEMP/PRESSURE TEMP/PRESSURE RELIEF VALVE RELIEF VALVE L L B B J Outdoor Sensor J C C Auto Adjusts for Maximum Efficiency M M F F E E Combining the Phoenix with an Air Handler G D D A A H G H A Unique and Highly K Efficient K Way to Provide Heat and Hot Water LOW WATER HTP ’s Unique Design LEFT SIDE LEFT SIDE LOW WATER FRONT VIEWFRONT VIEW CUT-OFFCUT-OFF HOT WATER HOT WATER OUTLET OUTLET Our laser welded, stainless steel tank is the best in the industry and will outlast any glass-lined tank. This light weight tank is built to last! The Phoenix has a 5:1 turndown ratio this reduces cycling and in- HIGH LIMIT HIGH LIMIT creases efficiency. The Phoenix is up to 96% efficient! The heat exchanger is a Stainless Steel / Cupronickel SAFETY SAFETY UPPER TEMP UPPER TEMP spiral design that SENSORexpands SENSOR and contracts AIR AIR rapidly with the change in temperature, eliminating scale build-up INTAKE INTAKE B (self-cleaning). B C C J J GAS GAS L LINE L PHOENIX WATER HEATER AND LINE SANITIZER BOOSTER DIMENSIONS M MSTANDARD FEATURES - Up to 96% Thermal Efficiency MODEL GAL. E AE B C D E F G H - Modulating Burner F F LOWER LOWER 5:1 Turndown Ratio PH100-55 / PH130-55 TEMP TEMP G - Vents in PVC, CPVC, Stainless Steel, SENSOR SENSOR 55 23” G 52” 45” 5” 14-3/4” 16-1/4” 5-1/4” 1” PH160-55 / PH199-55 H H ULC S636 - Limited Warranty 7 Year Residential PH100-80 / PH130-80 80 23” 72” 64” 5” N 17” 18-1/2” 7-3/4” 3-1/4” 3 Year (5 Year Option Available ) D PH160-80 D /APH199-80 A O N K K Commercial EXHAUSTEXHAUST O VENT VENT HEAT EXCHANGER HEAT EXCHANGER COLD WATER COLD WATER/ PH100-119 PH130-119 WHAT’S IN THE BOX INLET CONDENSATE LINE HOT OUTLET HOT OUTLET INLET 119 CONDENSATE 27” LINE74” 66-1/4” 7-1/2” 18-3/4” 21-1/2” 10-1/2” 5” - Intake PVC Tee w/ Screens PH160-119 / PH199-119 HEAT EXCHANGER HEAT EXCHANGER - Exhaust PVC Coupling w/ Screens COLD INLET COLD INLET - Installation Manual PH199-55SA (Sanitizer) 55 23” 52” 45” 5” 14-3/4” 16-1/4” 5-1/4” 1” - LP Conversion Kit (Natural Gas Models Only) OPTIONAL EQUIPMENT - Outdoor Sensor PHOENIX WATER HEATER AND SANITIZER BOOSTER SPECIFICATIONS - 2”, 3” PVC Concentric Vent Kit - 3”, 4” Stainless Steel Outside Air Intake/ Inlet/ Auxiliary Gas Line System Shipping Max. Temp Termination Vent Kit MODEL Btuh T. Efficiency / UEF - Condensate Neutralizer Exhaust Vent Outlet Conn. Conn. Relief Pipe Weight Limit - PC Connection Cable w/ Software PH100-55 100,000 2” 1” NPT 1” FNPT 3/4” 3/4” 175 LBS 160 F .89 - Sanitizer Booster Kit PH130-55 130,000 2” 1” NPT 1” FNPT 3/4” 3/4” 175 LBS 160 F 94% PH160-55 160,000 3” 1” NPT 1” FNPT 3/4” 3/4” 175 LBS 160 F 95% PH199-55 199,000 3” 1” NPT 1” FNPT 3/4” 3/4” 175 LBS 160 F 95% TP Ma •H d a PH100-80 100,000 2” 1-1/2” NPT 1” FNPT 3/4” 3/4” 235 LBS 160 F .93 eI n Amer i c n Amer i c PH130-80 130,000 2” 1-1/2” NPT 1” FNPT 3/4” 3/4” 235 LBS 160 F 95% eI a • HT Mad P PH160-80 160,000 3” 1-1/2” NPT 1” FNPT 3/4” 3/4” 235 LBS 160 F 96% PH199-80 199,000 3” 1-1/2” NPT 1” FNPT 3/4” 3/4” 235 LBS 160 F 95% PH100-119 100,000 2” 1-1/2” NPT 1” FNPT 3/4” 3/4” 405 LBS 160 F .90 PH130-119 130,000 2” 1-1/2” NPT 1” FNPT 3/4” 3/4” 405 LBS 160 F 96% SCAQMD Rule 1146.2 PH160-119 160,000 3” 1-1/2” NPT 1” FNPT 3/4” 3/4” 405 LBS 160 F 96% PH199-119 199,000 3” 1-1/2” NPT 1” FNPT 3/4” 3/4” 405 LBS 160 F 96% PH199-55SA 199,000 3” 1” NPT 1” FNPT 3/4” 3/4” 175 LBS 184 F 95% 25
You can also read